Install Instructions

LED Illuminated 3-Way Switch
Cat. No. L5613
Rated: 15A-120/277V AC
DI-000-L5613-20A
WARNINGS
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH ELECTRICAL CODES AND REGULATIONS.
CAUTIONS
Use this device with copper or copper clad wire only.
• To clean use a damp cloth with mild soap. DO NOT use disinfecting products, including foggers, sprays or other types of atomized cleaning agents.
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF
BEFORE WIRING!
2A. TO QUICKWIRE™: Remove insulation per strip gauge on device approx. 5/8" (1.6 cm). Insert straight #14 AWG solid copper wires into round
Quickwire™ holes. Quickwire™ terminals accept #14 AWG solid copper wires ONLY! For circuits with #12 AWG solid copper or copper clad wires,
use terminal screws instead. To replace or rewire after Quickwiring, gently press the tip of a small screwdriver in the release slot and back the wire
out gradually.
2B. TO SIDE WIRE: Remove insulation approx. 3/4" (1.9 cm). Loop wires clockwise 3/4 turn around terminal screws.
Tighten screws over wire loops to 14-18 in lbs.
2C. TO BACK WIRE: Remove insulation per strip gauge on device approx. 5/8" (1.6 cm). Insert straight wires under clamps of appropriate terminal screws.
Tighten screws firmly.
2D. The GROUND terminal on this device may be wired in the traditional side wire method or as follows: Slide wire straight between screw head and tab and
insert into hole per FIGURE 1 (no looping of wire required). Firmly tighten screw over wire.
3. Back and side wire terminal screws accept up to #12 AWG copper or copper clad wire.
4. Mount device using long mounting screws. Attach wallplate.
5. Restore power at circuit breaker or fuse. Installation is complete.
INSTALLATION
ENGLISH
For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) www.leviton.com
LIMITED 2
YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship
under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details visit
www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this
product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not
in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any
implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years.
Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits
or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada ULC to the attention of the
Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
Ground Insert Hole
Orifice d’insertion
Orificio para insertar
GROUND
INSERT
HOLE
Tab / Languette / Lengüeta
Ground Screw
Vis de terre
Tornillo a Tierra
Conductor
Fil
Conductor
Figure 1 / Figura 1
Wiring Diagram / Schéma de câblage / Diagrama de Cableado
Load
Charge
Carga
Line Hot (Black)
Ligne actif (noir)
Linea Fase (Negro)
Black / Noir / Negro
Neutro (Blanco)
Neutre (Blanc)
Neutral (White)
1
1
2
2
Travelers Brass Screw to Brass Screw
Conducteur ltinerant vis laiton à vis laiton
Viajeros Tornillo Latón a Tornillo Latón
2
To Common Terminal (Black Screw)
À la borne commune (Vis noire)
A Terminal Común (Tornillo Negro)
1
3
Ground (Green Screw)
Terre (vis verte)
Tierra (Tornillo Verde)
33