Specification

LG LAUNDRY
HOME APPLIANCES
QUICK INSTALL & CLEARANCES
For full installation directions/clearances please refer to
the corresponding User Manual and Installation Guide.
IMPORTANT
DLEX7600_E / DLGX7601_E
7.3 cu.ft. Super Capacity TurboSteam™ Dryer
DIMENSIONS AND CLEARANCES
CONNECTING ELECTRIC DRYERS
VENTING / DUCTWORK
Installation and service must be performed by a qualied installer, service agency,
or the gas supplier.
Use only a new stainless steel exible connector and a new
AGA-certied connector.
A gas shutoff valve must be
installed within 6 ft. (1.8 m) of
the dryer.
The dryer is congured for
natural gas when shipped from
the factory. Make sure that
the dryer is equipped with the
correct burner nozzle for the
type of gas being used (natural
gas or propane gas).
If necessary, the correct nozzle (for the LP nozzle kit, order part number
383EEL3002D) should be installed by a qualied technician and the change should
be noted on the dryer.
All connections must be in accordance with local codes and regulations. Gas dryers
MUST exhaust to the outdoors.
1" 1"
A
18" min
.
14" max.*
5"**
D
C
B
* Required spacing
** For side or bottom venting, 2-inch (5.1 cm) of spacing is allowed.
NOTE: Follow the guidelines below to maximize
drying performance and reduce lint buildup and
condensation in the ductwork. Ductwork and ttings
are NOT included and must be purchased separately.
Use 4-inch (10.2 cm) diameter rigid, semi-rigid or
exible metal ductwork.
The exhaust duct run should be as short as possible.
Use as few elbow joints as possible.
The male end of each section of exhaust duct must
point away from the dryer.
Use duct tape on all duct joints.
Insulate ductwork that runs through unheated areas
in order to reduce condensation and lint buildup on
duct surfaces.
Incorrect or inadequate exhaust systems are not
covered by the dryer warranty. Dryer failures or
service required because of such exhaust systems will
not be covered by the dryer warranty.
Correct Venting
Incorrect Venting
Ductwork is not provided with
the dryer. You should obtain the
necessary ductwork locally. The
vent hood should have hinged
dampers to prevent backdraft
when the dryer is not in use.
The total length of exible
metal duct must not exceed
8 ft. (2.4 m).
Deduct 6 ft. (1.8 m) for each
additional elbow. Do not use
more than four 90° elbows.
3/8" NPT gas
Connection
Stainless Steel Flexible
Connector
Gas Supply Shutof
f
Valve
1/8" NPT Pipe Plug
A 4-wire connection is required for all mobile and manufactured home
installations, as well as all new construction after January 1, 1996.
A 3-wire connection is NOT permitted on new construction after January 1,
1996.
A UL-listed strain relief is required.
Use a 30-amp, 240-volt, 4-wire, UL-listed power cord with #10 AWG-minimum
copper conductor and closed loop or forked terminals with upturned ends.
Wall Cap Type
Number
of 90°
Elbows
Maximum
length of 4-inch
diameter rigid
metal duct
Recommended
a
a
a: 4" (10.2 cm)
0 65 ft.(19.8 m)
1 55 ft.(16.8 m)
2 47 ft.(14.3 m)
3 36 ft.(11.0 m)
4 28 ft.(8.5 m)
Use only for short
run installations
b
b: 2.5" (6.35 cm)
055 ft.(16.8 m)
147 ft.(14.3 m)
241 ft.(12.5 m)
3 30 ft.(9.1 m)
4 22 ft.(6.7 m)
CONNECTING THE GAS SUPPLY
DIMENSIONS
A Width 27"
B Height 44 1/4"
C Depth 28 15/16"
D Depth with Door Open 50 1/4"
Carton (WxHxD) 29 1/2” x 47 1/8” x 30 31/32”
ENERGY / POWER SOURCE
ENERGY STAR® Qualied Yes
Ratings CSA Listed
Electrical Requirements 120V, 15 Amps (Gas) / 240V, 30 Amps (Electric)
Type Gas (DLGX3701_) / Electric (DLEX3700_)
BTU Rating 10,000 Feet
© 2018 LG Electronics USA, Inc. All rights reserved. "LG Life’s Good" is a registered trademark of LG Corp. All other product and brand names are trademarks or registered trademarks of their respective owners. Design, features and specifications are subject to
change without notice. Non-metric weights and measurements are approximate. Some features may require Internet access. Content and services may vary by product and are subject to change without notice. 9/26/18