Owner's Manual EvolutionTM LGR Dehumidfier 115v Model DRI-EAZ PRODUCTS, INC. 15180 Josh Wilson Road, Burlington, WA USA 98233 Fax: (360) 757-7950 Phone US: (360) 757-7776 www.dri-eaz.com 07-01480C LW 04-13 Copyright 2007 Dri-Eaz Products, Inc.
Owner's Manual Dri-Eaz EvolutionTM LGR Dehumidfier 115-volt model READ AND SAVE THESE INSTRUCTIONS Use and Operation WARNING FIRE AND ELECTRIC SHOCK HAZARD Unit must be electrically grounded. •Insert 3- prong plug on power cord directly into matching grounded receptacle. •Do not use adaptor Keep wiring and motor dry. •Do not operate in standing water •Do not operate in rain or snow. •If electrical components become wet, allow them to dry before using. Read and understand manual before use.
READ AND SAVE THESE INSTRUCTIONS Diagram 1 CAUTION Do not operate the Evolution LGR dehumidifier at temperatures above 90° F (32° C). This can cause damage to both the machine and the structure’s contents. Over-dried materials (especially wood products) may crack, shrivel, or discolor. Use of a dehumidifier in high-heat conditions will reduce its effeciency and the life of the machine. Managing temperature rise Dri-Eaz dehumidifiers warm the air as they remove moisture.
READ AND SAVE THESE INSTRUCTIONS HOW TO USE THE TOUCHPAD CONTROL KEYS The Touchpad on the Evolution LGR has one display and four keys. The normal display messages are: DEHUMIDIFIER OFF DEHUMIDIFIER ON TOTAL HRS JOB HRS IIlustration of Touchpad CMPRSR DELAY PUMP PURGING DEFROST ON GET SERVICE ERO1 When you first plug in the unit, the touchpad display will cycle continuously through three messages: DEHUMIDIFER OFF, TOTAL HOURS, and JOB HOURS. ON-OFF. Press the ON-OFF key to turn the unit on or off.
READ AND SAVE THESE INSTRUCTIONS WARNING Electric Shock Hazard Unplug unit before performing any maintenace. Never use a water hose or pressure washer to clean coils; water could enter the electrical campartment causing a shock hazard. Follow cleaning instructions in manual. PURGE. Press the PURGE key to empty water from the pump reservoir. During normal operation, the pump purges automatically every six minutes, or whenever the reservoir is full.
READ AND SAVE THESE INSTRUCTIONS Monthly Remove housing, in order to locate the coils, catch basin, float shaft, and drain hose. • Check coils, and clean when visibly dirty. Dirty coils can cause the unit to over heat. 1. Unplug unit 2. Remove housing, locate coils and allow coils to dry if wet. 3. Vacuum both sides of the coils until clean, being careful not to let the nozzle touch the fins; as that may cause damage by bending them. 4.
TROUBLESHOOTING For any problems not listed below, call your local distributor or contact our Service Department toll free at 888-8673235. CAUSE PROBLEM Unit does not operate SSSOLUTION No power to machine Switch not turned on Unit needs 5 minutes before restart Overload preventing start up Plug in the unit; check power at outlet. Turn on switch. Switch off unit, wait 5 minutes before starting. Reduce room temperature below 90° F (32° C).