website http://www.lgservice.com ENGLISH ITALIANO DUTCH ESPAÑOL OWNER'S MANUAL PORTUGUÊS LG Ventilator ∂ÏÏ¿‰· LG FRANÇAIS DEUTSCH IMPORTANT • Please read this owner's manual carefully and thoroughly before installing and operating your product. • Please retain this owner's manual for future reference after reading it thoroughly.
Ventilator Owner’s Manual TABLE OF CONTENTS Safety Precautions.........................3 FOR YOUR RECORDS Write the model and serial numbers here: Model # Prior to Operation ..........................6 Serial # You can find them on a label on the side of each unit. Dealer's Name Introduction ....................................7 Electrical Safety .............................8 Characteristics ...............................9 Operating Instructions.................10 Maintenance and Service ........
Safety Precautions Safety Precautions This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage. ■ Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. ■ Installation Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit. For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.
Safety Precautions For re-installation of the installed product, always contact the dealer or an Authorized Service Center. Do not open the maintenance cover of the main body during operation. Use the outdoor air suction hole with the net installed to ensure that birds could not come in. • There is risk of fire, electric shock, explosion or injury. • Otherwise, it may cause electrical shock. • Remove estrange things like the bird’s nest. Otherwise, it may cause scarcity of indoor oxygen.
Safety Precautions Turn the breaker off when cleaning or maintaining the product. • There is risk of product damage or failure, or unintended operation. Don’t touch a dedicated circuit or breaker with wet hands. • There is risk of electric shock. Avoid fire equipment • There is risk of fire. Use a firm stool or ladder when cleaning or maintaining the roduct. • Be careful and avoid personal injury. ■ Installation Use two or more people to lift and transport the product. • Avoid personal injury.
Prior to Operation Prior to Operation Preparing for operation 1. Contact an installation specialist for installation. 2. Plug in the power plug properly. 3. Use a dedicated circuit. 4. Do not use an extension cord. 5. Do not start/stop operation by plugging/unplugging the power cord. 6. If the cord/plug is damaged, replace it with only an authorized replacement part. Usage 1. Being exposed to direct airflow for an extended period of time could be hazardous to your health.
Introduction Introduction Symbols used in this Manual ENGLISH This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that could cause harm to the ventilator. NOTICE This symbol indicates special notes. Features WARNING: This appliance should be installed in accordance with national wiring regulations. This guide acts as a guide to help to explain product features. 5 1 2 6 3 7 4 8 1. Maintenance cover 2.
Electrical Safety Electrical Safety WARNING: This appliance must be properly grounded. To minimize the risk of electric shock, you must alway plug into a grounded outlet. Preferred method Ensure proper ground exists before use WARNING: Do not cut or remove the grounding prong from the power wire.
Characteristics Characteristics Ventilation via Total Heat Exchanger • The outdoor air heat exchanged is supplied to indoor. Operate the ventilator in the Ventilation via Total heat exchanger in summer/winter when cool/heat operation is done. Damper Exhaust air Return Air Outdoor air Supply Air Total Heat Exchanger Normal Ventilation Exhausts the polluted indoor-air directly without via the Total Heat Exchanger.
Operating Instructions Operating Instructions (Accessory) LCD Remote Controller (Ventilation System Remote Controller : PZRCUSB0) EXTERNAL 1 VENTILATOR OPERATION Linked Run Dual Remote Central Run Heat XCH PLASMA e-SAVER fresh Auto Lo Auto Auto Normal Delay Time Timer SUB FUNCTION Hi SHi Heater Preheat Defrost Humidify Fan Speed Filter Time Program set Sun Mon Tue Wed Thu ZONE 1234 Fri Sat On Off Set no.
Operating Instructions Method to Operate and Select Air Volume VENTILATOR OPERATION Linked Run Dual Remote Central Run Heat XCH PLASMA e-SAVER fresh Auto Lo Auto Auto Normal Delay Time Timer SUB FUNCTION Hi SHi Heater Preheat Defrost Humidify Fan Speed Filter Time Program set Sun Mon Tue Wed Thu ZONE 1234 Fri Sat On Off Set no. Timer Timer Cancel Program Week fresh Plasma Min Auto Holiday Set/Clr Hour Press the Operation/Stop button.
Operating Instructions Ventilation Mode Setting EXTERNAL VENTILATOR OPERATION Linked Run Dual Remote Central Run Heat XCH PLASMA e-SAVER fresh Auto Lo Auto Auto Normal Delay Time Timer SUB FUNCTION Hi SHi Heater Preheat Defrost Humidify Fan Speed ZONE 1234 Filter Time Program set Sun Mon Tue Wed Thu Fri Sat On Off Set no. Timer Timer Cancel Program Week fresh Select the desired operation mode by pressing the Ventilation Mode button.
Operating Instructions Rapid Ventilation/Power Saving Ventilation Rapid Ventilation VENTILATOR OPERATION Linked Run Dual Remote Central Run Heat XCH PLASMA e-SAVER fresh Auto Lo Auto Normal Delay Time Timer SUB FUNCTION Hi SHi Heater Preheat Defrost Humidify Fan Speed Filter Time Program set Sun Mon Tue Wed Thu ZONE 1234 Fri Sat On Off Set no.
Operating Instructions Additional function Setting of current time • You can easily set the current time. EXTERNAL VENTILATOR OPERATION Linked Run Dual Remote Central Run Heat XCH PLASMA e-SAVER fresh Auto Lo Auto Auto Normal Delay Time Timer SUB FUNCTION Hi SHi Heater Preheat Defrost Humidify Fan Speed Filter Time Program set Sun Mon Tue Wed Thu 1 ZONE 1234 Fri Sat On Off Set no. Timer Press the [Hour] button on the adjustment part of the remote controller.
Operating Instructions Weekly Reservation Setup No reservation operation can be set if the current time not is not set.
Operating Instructions Holiday Setup Example) In the case it's holiday on Tuesday. • Automatically turns off when the reservation day set up. Press the [Program] button on the adjustment part of the remote controller. • Display part flickers as following figure.
Operating Instructions On/Off Reservation ‘On’ Reservation • This function will automatically turn ON the units at set time. Press [Timer] button on the adjustment part of the remote controller. 2 Set the desired time with [Hour, Min] button. Timer Sun On Timer Timer Cancel Program Week fresh Auto Hour Min Holiday Plasma Set/Clr Hour TIME RESET Min Press [Timer] button once more or Timer press the Cancel button in order to cancel reservation.
Maintenance and Service Maintenance and Service Handling and Cleaning To prevent function of the ventilator deteriorating, clean dust adhered to the air filter and total heat exchanger regularly. Cleaning Cycle - Air filter: More than once every 6 months. - Total heat exchanger: More than once every 2 years (Cleaning cycle may increase according to pollution degree.) Method to take each part out 1. Remove the maintenance cover.
Maintenance and Service Method to Clean and Replace Each Part 1. Cleaning of Air Filter Clean once every 6 months. Cleaner • After washing with water, dry well in the shade. (Do not expose the air filter to direct sunlight or heat from a fire when drying it) • If the air filter is damaged, purchase it from the service center or professional agent. 2. Cleaning of Total Heat Exchanger Suck dusts adhered to the surface of the Total heat exchanger with a cleaner.
Maintenance and Service Assembly and Check after Maintenance 1. Assembly of Total heat exchanger Securely put the corner parts (4 or 6 parts) of the Total heat exchanger into the holder for assembly and slide them into the inside of the main body. Total Heat Exchanger Main Body Assemble the air filter into the holder structure. Holder for Total Heat Exchanger 2. Assembly of air filter Assemble the air filter into the holder structure of the Total heat exchanger.
Check Item prior to notify a failure Check Item prior to notify a failure Symptom The Product doesn't work through you press the 'ON' switch Even though you change the fan speed, the operation mode doesn't change and it changes to 'Auto or Low' Counter-measure Is power not supplied? Supply Power Is Air Filter, Total heat exchanger clogged severely? Follow cleaning and changing method. Is the Indoor temperature less than -10°c or more than 45°C? It's standby mode for protecting Total Heat Exchanger.
Ventilator
P/No.: 3828A20468M Printed in Korea After reading this manual, keep it in a place easily accessible to the user for future reference.