Owner's Manual

45
TROUBLESHOOTING
ENGLISH
Problem Possible Causes & Solution
Excess static in
clothes after drying
Fabric softener is not used or used incorrectly.
Use a fabric softener or the REDUCE STATIC option, if equipped, to reduce
static electricity. Be sure to follow the manufacturer’s instructions.
Clothes dried too long (overdried).
Overdrying a load of laundry can cause a buildup of static electricity. Adjust
settings and use a shorter drying time, or use MANUAL DRY cycles. Select a
LESS DRY setting on SENSOR DRY cycles, if necessary.
Drying synthetics, permanent press, or synthetic blends.
These fabrics are naturally more prone to static buildup. Try using fabric
softener, or use LESS DRY and/or shorter TIME DRY time settings.
Clothes have
damp spots after a
Sensor Dry cycle.
Very large load or very small load.Single large item such as a blanket or
comforter.
If items are too tightly packed or too sparse the sensor may have trouble
reading the dryness level of the load. Use a TIME DRY cycle for very small
loads.
Large, bulky items such as blankets or comforters can sometimes wrap
themselves into a tight ball of fabric. The outside layers will dry and register on
the sensors, while the inner core remains damp. When drying a single bulky
item, it may help to pause the cycle once or twice and rearrange the item to
unwrap and expose any damp areas.
To dry a few remaining damp items from a very large load or a few damp spots
on a large item after a sensor cycle has completed, empty the lint trap, then set
a TIME DRY cycle to finish drying the item(s).
Error Codes
Problem Possible Causes & Solution
Error code: tE1 through tE7
Temperature sensor failure.
Turn off the dryer and call for service.
Display shows error code: PS
Power cord is connected incorrectly.
Check the connection of the power cord to the terminal block.
*Flow Sense™ indicator
shows four bars during the
drying cycle or the display
shows “d80” after drying
* This warning light is
not a dryer failure and is
not covered by the dryer
warranty. Contact a duct
cleaning service to set up
an appointment to have your
exhaust system cleaned and
inspected.
Exhaust system is too long or has too many turns/restrictions.
Install a shorter or straighter duct run. See the Installation
Instructions for details.
Partial blockage of the ductwork due to lint buildup or other
foreign object.
Ductwork should be checked/cleaned immediately. Dryer can be
used in this condition, but drying times will be longer and energy
consumption will increase.
The appliance has detected a restriction in the external dryer
venting.
If exhaust restrictions are sensed by the Flow Sense™ system,
the indicator will remain on for 2 hours after the end of the cycle.
Opening the door or pressing the Power button will turn off the
display.