Most three phase duplex panels are designed to operate with three
or four oat systems. The three oat system is standard, perform-
ing the common pump stop, lead pump start, and lag pump start/
high level alarm functions. The four oat system utilizes separate
oats for each function.
NOTE: Options ordered may affect the number of oats and
their functions. Please reference the schematic provided with
the control panel for proper installation.
Installation of Floats
CAUTION: If control switch cables are not wired and mounted in
the correct order, the pump system will not function properly.
WARNING: Turn off all power before installing oats in pump cham-
ber. Failure to do so could result in serious or fatal electrical shock.
1. Use oat label kit to identify and label cables on both oat and
stripped ends (stop, lead, lag, alarm, etc.). See schematic for
oat options.
2. Determine your normal operating level, as illustrated in Figures
1 & 2.
3. Mount oat switches at appropriate levels as illustrated in Fig-
ures 3-5. Be sure that oats have free range of motion without
touching each other or other equipment in the basin.
If using the mounting clamp; follow steps 4-6.
4. Place the cord into the clamp as shown in Figure 5.
5. Locate the clamp at the desired activation level and secure the
clamp to the discharge pipe as shown in Figure 5.
NOTE: Do not install cord under hose clamp.
6. Tighten the hose clamp using a screwdriver. Over tightening
may result in damage to the plastic clamp. Make sure the oat
cable is not allowed to touch the excess hose clamp band
during operation.
NOTE: All hose clamp components are made of 18-8
stainless steel material. See your SJE-Rhombus
®
supplier for
replacements.
FIGURE 5: Mounting clamp detail
3.5 inch (9 cm)
tether length
FIGURE 3: Internally weighted oat
7"
suspended cable
approximate
activation level
FIGURE 2: Four oat duplex
5
FIGURE 1: Three oat duplex
5
FIGURE 4: Float with cable weight
suspended cable
4"
tether
length
CABLE
WEIGHT
approximate
activation level