Problem
Cause
Correction
Pump will not turn on
Blown fuse or other interruption of
power; improper voltage.
Check that the unit is securely plugged in.
Have an electrician check all wiring for proper
connections and adequate capacity.
Defective switch or build-up on tank
wall restricting free movement of
float switch.
Check that float is free to move. If build-up
restricts float, clean and reinstall. Otherwise,
consult factory.
Pump runs or hums
but does not pump
Discharge is blocked or restricted.
Check the discharge line for blockage, including
ice if the line passes through or into cold areas.
Check valve is stuck closed or
installed wrong.
If present, remove and examine for freedom of
operation and proper installation.
Total lift height has been reached
(see Fig. 2)
Try routing pipe to a lower level. If not possible,
a larger pump may need to be installed in the
basin.
Pump impeller is jammed.
*Disassemble the receiver and bottom base of
pump. Remove foreign material. Reassemble.
Defective switch.
Check that float is free to move. If build-up
restricts float, clean and reinstall. Otherwise,
consult factory.
Pump does not turn off
Defective switch or build-up on tank
wall restricting free movement of
float switch.
Check that float is free to move. If build-up
restricts float, clean and reinstall. Otherwise,
consult factory.
Pump sprays water
from side of housing
This is normal due to factory drilled
air-bleed hole
No action required
Pump operates noisily
Foreign objects in impeller cavity.
*Disassemble the receiver and bottom base of
pump. Remove foreign material. Reassemble.
Broken impeller
Consult the factory for information regarding the
replacement of impeller.
3. Maintenance and Troubleshooting