Design Guide

30
Freestanding/Semi Built In Models
Ventilation Requirements 24", 30", 48" and 60" Models
Therefrigeratorisdesignedtoallowproperairowwhen
the appliance is installed up against the wall.
A minimum space of 1 1/2" is required behind the cabinet
when venting above an upper cabinet which is installed
ushtothetopoftheappliance.
B - Side view
Cabinet
Refrigerator
Do not restrict the air flow. The opening can either be
directly over the appliance
1
, above the cabinet and
below the ceiling
2
or through a vent installed in a soffit
3
.
The cabinet height as specified at 80” (2032 mm) will
create a 1-5/16” (33 mm) gap above the appliance
providing optimal air flow over the top of the appliance for
its efficient operation.
To have the same air flow for CS 1410 appliances, the
cabinet opening height must be 73-3/4" minimum.
Be sure to consider the possibility of having to raise
some of the leveling legs in order to level the appliance
when installing. If you adjust the height of the appliance -
it will effectively reduce air flow. Therefore leave yourself
some room for adjustment.
IMPORTANT
The section between the freezer door and the floor must
not be covered.
1
2
3