Operating Instructions and Owner’s Manual LF2WP, LF2WP-CA, LF3WP, LF3WP-CA, LF4WP, LF4WP-CA PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING YOUR NEW LIFAN Power USA Water Pump (-CA) Indicates this unit is CARB Certified for California
PLEASE READ THE FOLLOWING INSTRUCTIONS! 1. Unit Shipped with “NO OIL” in Engine or where applicable pumps and/or accessories. Check and fill with proper oil as outlined in the Owner’s Manual for the respective product. 2. For repair under Warranty or questions concerning Warranty, DO NOT return this product to the Store where purchased. Follow the procedures as outlined in the “WARRANTY POLICY” and “WARRANTY REGISTRATION” in the Owner’s Manual. For any questions visit www.lifanpowerusa.
TABLE OF CONTENTS Preface 4 Product Specifications 5 Safety Instructions 6 Controls and Features 9 PRE-OPERATING INSTRUCTIONS 10 Connecting Water Inlet Hose 10 Connecting Water Outlet Hose 11 Engine Oil Level Check 12 Engine Fuel Level Check 13 Air Cleaner Element Check 14 Pump Water Capacity Check 15 Operation of Water Pump 16 Transporting and Storing the Unit 19 Maintenance 21 Troubleshooting 25 Water Pump Safety 26 Limited Warranty Policy 27 3 LIFAN Power USA 2205 Indust
Preface Thank you for choosing LIFAN Power USA for your Power Equipment Needs. LIFAN Power USA prides itself on providing quality products at affordable pricing, creating the “Best Equipment Value on Today’s Market!” All LIFAN Power USA products are manufactured utilizing the latest technology. Built with quality components, your new Power Equipment Product will give you years of dependable service.
Product Specifications Pro Series Water Pumps LF2WP (-CA) LF3WP (-CA) LF4WP (-CA) 2in (50mm) 3in (80mm) 4in (102mm) 3600rpm 3600rpm 3600rpm 9500gph (35961.41 L/hrs) 14260gph (64827.27L/hrs) 22983gph (104.482.8L/hrs) Suction Lift 19.68ft (6m) 19.68ft (6m) 14.76ft (4.5m) Maximum Pump Head 85.3ft (26m) 98.42ft (30m) 78.
Safety Instructions This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. For your safety read this manual carefully. Become familiar with the proper operation, care, and maintenance of your LIFAN Power USA water pump. The safety and alert symbol ( ) is used with a signal word (CAUTION, DANGER, WARNING), a pictorial and/or safety message to alert you to hazards.
Safety Instructions (continued) WARNING! Rapid recoil of starter cord (kickback) may pull hand and arm forward toward engine at a rapid rate. Broken bones, bruises, sprains, and fractures may result. When starting engine, pull cord slowly until tension is felt, then pull rapidly to avoid kickback. WARNING! Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.
Safety Instructions (continued) WARNING! While engine is running temperature may exceed 150°F (65°C). Server burns may occur. Exhaust heat/gasses can ignite combustibles, structures or damage fuel tank causing a fire. Do NOT touch hot surfaces and do avoid exhaust gasses. Allow water pump to cool before touching. Keep at least 6 ft. (183cm) clearance on all sides of water pump including overhead clear. Reflective exhaust heat may damage fuel tank causing fire.
Controls and Features Legend 1. Throttle Valve Lever – Controls Engine Speed 2. Choke Lever – LF4WP Model: Before starting cold water pump, pull the choke pin outward from water pump to activate the choke lever. After allowing water pump to run for a few seconds, push pin inward toward water pump. LF2WP & LF3WP Models: Before starting cold water pump, rotate the choke lever to the left until resistance is felt. After starting the water pump, rotate the choke lever to the right to disengage. 3.
Pre-Operating Instructions: Connecting Water Inlet Hose Use commercially available hose, hose joint, and clamp. The water inlet hose must be of continuous structure and be non-folded. The length of the hose should be no more than required. The effect of suction is greatest at shorter distances from the water surface. Suction time varies with the length of the water inlet hose. The filter matching with the water pump should be mounted to the end of the water inlet hose with a hose clamp.
Pre-Operating Instructions: Connecting Water Outlet Hose Use commercially available hose, hose joint, and clamp. A short hose with a big diameter will provide the best performance. A long hose with a small diameter will increase flowing resistance and decrease the power output of the water pump. NOTE: Tighten the hose clamp to keep from disengaging during operation under high pressure. 11 LIFAN Power USA 2205 Industrial Park Road Van Buren, AR 72956 866-471-7464 www.lifanpowerusa.
Pre-Operating Instructions: Engine Oil Level Check CAUTION: Running engine with insufficient engine oil can cause severe damage to the engine. The engine performance and service life is directly dependent of the quality of the engine oil. Do NOT use filthy engine oil or vegetable oil. Check engine oil level only with engine stalled and with unit on level ground. o Use 4-Stroke Gasoline Engine Oil equivalent in quality with SF, SG from API. Oil velocity varies with average environmental temperature.
Pre-Operating Instructions: Engine Fuel Level Check CAUTION: Gasoline is extremely flammable. Keep away from ignition sources. Fuel unit only in well-ventilated areas with the engine stalled. Do NOT smoke near unit. Do NOT spill fuel out of the fuel tank. Spilled gasoline and gasoline vapor may ignite. If gasoline is spilled, wipe completely dry before starting the engine. Avoid repeated or sustained breathing of gasoline. Avoid skin contact with gasoline.
Pre-Operating Instructions: Air Cleaner Element Check CAUTION: Do NOT run the engine without air cleaner element installed. Operation of engine without air cleaner element installed will result in the inhalation of dirt, dust, and other debris into the engine and through the carburetor. This will result in premature wear of the engine. To Check Air Cleaner Element: 1.
Pre-Operating Instructions: Pump Water Capacity Check CAUTION: Do NOT run engine without water inside the pump. Operation of engine without water inside the pump will cause the pump to overheat. Prolonged operation of engine without water inside the pump will damage the pump gasket and impeller. If water within the pump is not full, shut off the engine at once and fill the pump after allowing the unit to cool. To Check Pump Water: 1. 2. 3. 4. Remove Water Filler Cap.
Operation of Water Pump Water Pump Use Location: WARNING! Running water pump gives off carbon monoxide gas. It is odorless, colorless, and highly toxic. Breathing carbon monoxide gas can leads to fainting, nausea or may result in death. Only operate water pump outdoors. Prevent exhaust gas from entering, through windows doors or ventilation intakes, any confined areas. DO NOT operate water pump inside any enclosed or roofed areas.
1. Operation of Water Pump (continued) Starting the Engine: Refer to the Controls and Features section for additional diagrams and definitions. 1. Prime the pump. 2. Move the fuel cock to the “ON” position. 3. To start a cold engine, refer to instruction in the Controls and Features section – 2. Choke lever. To restart a warm engine, leave the choke level in the “OPEN” position. 4. Move the throttle valve lever away from the “LOWER” position, about 1/3 of the way toward the “UPPER” position. 5.
Operation of Water Pump (continued) Stopping the engine: Refer to the Controls and Features section for additional diagrams and definitions. IN EMERGENCY: 1. Turn the engine switch to the “OFF” position. NORMAL PROCEDURE: 1. 2. 3. 4. 5. Move the throttle valve lever to the “LOWER” position. Turn the engine switch to the “OFF” position. Turn the fuel cock to the “OFF” position. Remove the water drain plug and drain the pump chamber.
Transporting and Storing the Unit CAUTION: To avoid fire, allow water pump to cool down for at least twenty (20) minutes before transporting or storing the unit. Always transport and store the unit with the fuel cock in the “OFF” position. Always keep unit in horizontal position to the ground to prevent fuel from spilling. Spilled gasoline and gasoline vapor may ignite. Gasoline is extremely flammable and explosive.
Transporting and Storing the Unit (continued) 9. Add the recommended amount of fuel stabilizer, in accordance with the amount recommended by the manufacturer of the fuel stabilizer, to the unused gasoline left in the unit’s tank. 10. Place the unit in a clean, dry, and secure location. 11. Cover the unit to protect from dust. 20 LIFAN Power USA 2205 Industrial Park Road Van Buren, AR 72956 866-471-7464 www.lifanpowerusa.
Maintenance MAINTENANCE SCHEDULE PROCEDURE Engine Oil Check TIME Each Use After Each 40 Hours of Use (For Initial Break Replace Engine Oil in – After First (1st) 10 Hours of Use Check Each Use/Replace As Needed or After Air Cleaner Filter Every 100 Hours of Use Impeller Check After 300 Hours of Use or After First Year Air Cleaner Wash When Needed Spark Plug When Needed Check & Re-adjust annually or after 300 Valve Clearance Hours of Use Fuel Tank Replace Every 3 Years Based on Condition NOTE: Refer to Foll
Maintenance (continued) OIL CHANGE PROCEDURES (continued): 4. Replace the dipstick on your engine. PROPER MAINTENANCE OF YOUR UNIT WILL INCREASE THE LIFE OF YOUR PRODUCT. THE OIL MUST BE CHANGED ON A REGULAR BASIS FOR PROPER OPERATION, AND RELIABILITY AND TO ALSO MAINTAIN YOUR WARRANTY ON THIS PRODUCT. AIR CLEANER MAINTENANCE: 1. Remove the clip (item 9 in “Air Cleaner A” below) or the wing nut (item 7 in “Air Cleaner B” below) to remove and check the air filter element. 2.
Maintenance (continued) SPARK PLUG MAINTENANCE: 1. Remove Spark Plug Cap (refer to "Spark Plug Cap Removal” figure below.) 2. Remove Spark Plug with socket and handle supplied with your unit (refer to “Spark Plug Removal” figure below.) 3. Clean any carbon build-up around the Spark Plug. 4. Check the Spark Plug Gap and adjust if necessary. 0.30-inch gap. 5. Lubricate the threads of the spark plug with anti-seize compound or engine oil. 6. Re-install the Spark Plug and Spark Plug Cap.
Maintenance (continued) FUEL SYSTEM MAINTENANCE (continued): diagram below) and either clean or replace the fuel filter element. Re-assemble the fuel filter element (refer to “Fuel Filter Element Assembly” diagram below.) Fuel Filter Element Removal Fuel Filter Element Assembly USAGE IN HIGH ALTITUDE REGIONS: In regions with high altitude, the standard carburetor produces overly dense combinations of fuel and air, which result in decreased engine performance and increased fuel consumption.
Troubleshooting IF THE ENGINE WILL NOT START: 1. Check to ensure switches are in the “ON” position. 2. Check engine oil level. The unit possesses a Low Oil Shutdown feature that will not allow your engine to start if the oil is below safe operating levels. This feature is installed to increase the life of your engine and prevent engine damage. If oil level is low, fill to the full mark on dipstick. Refer to the PreOperating Instructions: Engine Oil Check section for exact oil type and amounts. 3.
Water Pump Safety 1. Never operate a gasoline engine powered product in any enclosed spaces, as they product deadly Carbon Monoxide Poisonous Gases. 2. Do NOT operate your power equipment in inclement weather such as rain, snow, and/or sleet. 3. Do NOT operate your power equipment within five (5) feet of any flammable materials. 4. When refueling your power equipment never smoke or refuel near any flame or ignition devices. Never refuel while the unit is running.
This warranty is limited to the following LIFAN Power and Storm Series products that are distributed by the Equipsource LLC, dba LIFAN Power USA, located at 2205 Industrial Park Road, Van Buren, AR 72956.
Please Read this Owner’s Manual Carefully Before Operating Your New Water Pump. This Owner’s Manual includes the operation and maintenance of the LF2WP, LF2WP-CA, LF3WP, LF3WP-CA, LF4WP, & LF4WP-CA. Thank you for purchasing our Pro Series Water Pump! All information in this publication is based on the latest product information available at the time of approval for printing. We reserve the right to make changes at any time without notice and without incurring any obligation.