Installation Guide

WARNING
To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
CAUTION
This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. Do not use with storable
pools. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage.
A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original integrity and has a
maximum dimension of 18 feet (5.49m) and a maximum wall height of 42 inches (1.07m).
CAUTION
For hot tubs and spa pumps, do not install within an outer enclosure or beneath the skirt of a hot tub or spa unless so marked.
SECTION I. GENERAL INFORMATION
A. Wiring.
1. Be sure all electrical breakers and switches are turned
off before wiring motor.
2. Be sure the supply line voltage matches the motor voltage
listed on the motor plate (example 230 VAC or 115
VAC). If they do not match, permanent motor damage may
occur.
3. Use #12 AWG for wire runs upto 100 feet (30.5 meters) and
#10 AWG for lengths longer than 100 feet (30.5 meters).
When in doubt use a heavier gauge (larger diameter) wire. For
more information , see CHART 1.
4. Use strain relief and be sure all electrical connections are clean
and tight.
5. Cut wires to the appropriate length so they don’t overlap or
touch when connected to the terminal board.
6. Permanently ground the motor using the green ground terminal located on the inside of the motor canopy or
access plate, see Figure 1. Use the correct wire size and type specified by National Electrical Code. Make sure
the ground wire is connected to an electrical service ground.
WARNING
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
This pool pump must be installed by a licensed or certified electrician or a qualified pool installer in accordance with the
2008 National Electrical Code (“NEC”) and/or all applicable local codes and ordinances. The specific section of NEC
covering your pump may vary depending on your location. Some states, and/or municipalities may not have adopted
the current NEC code. In this case your state or local code may only be applicable and/or an earlier edition of the NEC
may apply. Please check your local and state codes and regulations before commencing any installation of this pump.
Improper installation could create, among other things, an electrical hazard which may result in death or serious injury
to pool users, installers, or others due to electrical shock, and/or property damage. Always disconnect power to the
pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury
to service people, users or others due to electric shock. Read all servicing instructions before working on the
pump.
)GWA(SEZISERIWYLPPUS
)rewopesrohybhtgneldnaezis(
phstlov511stlov032
.tf05.tf001.tf051.tf05.tf001.tf051
3/1414121414141
2/1412101414141
4/3212101414141
121018
414141
½101018414121
20188412121
3--- 212101
Chart 1.
1