TDS

TECHNICAL DATA SHEET
Effective: October 25, 2018 Page 1 of 1 (866) 843-8453 | homedepot.com
PHYSICAL PROPERTIES (FLOATING MULTILAYER MODULAR FLOORING) - 7.0MM GAUGE / 6MIL WEAR LAYER
Collection Plank - Wide
Size
8.7"x47.6" (220mm x 1210mm)
Overall Gauge 7.0mm (0.276”)
Wear Layer 6mil (0.15mm)
Top Layer 2.0mm (0.079”) LVT
Core 4.0mm (0.157”) Rigid Core
Pad 1.0mm (0.039”) HDPE
Use Light Commercial & Residential
Profile Square Edge
Finish Enhanced Ceramic Bead
Ultra-Fresh Included in Finish and Pad
Embossing(s) Handscraped, In-Register, Natural Timber
Pieces/Carton 7 pieces
Coverage/Carton 20.06 Sq.Ft. (1.86 Sq.M.)
Limited Warranty
Light Commercial - 5 Years
Residential - Lifetime
STANDARDS – SAFETY & PERFORMANCE
Standard Description Requirements Results
ASTM E648
Critical Radiant Flux (Radiant Panel) Class I: ≥ 0.45 W/cm
2
Passes Requirements
1
ASTM E662 Smoke Density Flaming & Non-Flaming ≤ 450 Passes Requirements
2
ASTM D2047 Coefficient of Friction (Slip Resistance) Not Applicable (No Official Requirements) ≥0.6 (Dry)
ASTM F970 Static Load No Requirements if Wear Layer < 20mil Not Applicable
SIM Test Static Load Limit Test to Limit (±0.005”) ≥500psi
ASTM F2199 Dimensional Stability ≤0.25% / lineal ft. Surpasses Requirements
ASTM F925 Chemical Resistance No more than “Slight Change” Surpasses Requirements
ASTM F1514 Resistance to Heat Average ΔΕ < 8.0 Surpasses Requirements
ASTM F1515 Resistance to Light Average ΔΕ < 8.0 Surpasses Requirements
ASTM G21 Antifungal Activity Not Applicable (No Official Requirements) Top: 0-1; Bottom: 0-1
3
ASTM F963 Heavy Metals Refer to Standard Passes Requirements
ASTM D7823 Phthalates Refer to CPSIA
4
Passes Requirements
STANDARDS – SOUND
Assembly ASTM E90 ASTM E492 ASTM E2179 Results (Remarks)
6” Concrete Slab
STC 50 IIC 50 ΔIIC 24
All tested assemblies pass IBC
5
requirements of
STC ≥ 50 and IIC ≥ 50 for multi-story dwellings
8” Concrete Slab STC 53 IIC 55 Not Applicable
6” Concrete Slab with Drop-Ceiling STC 61 IIC 69 Not Applicable
Notes
1) ASTM E648 - Critical Radiant Flux (Radiant Panel): Passes Requirements for Class I per International Building Code (IBC) 2018 & NFPA 101 Life Safety Code
2) ASTM E662 - Smoke Density: 450 is the limit established by many state, county, and/or local building and/or fire codes, but is not set as a limit for (resilient) flooring products
nationwide. Thus, Smoke Density requirements for flooring products may vary from jurisdiction to jurisdiction.
3) ASTM G21 - Antifungal Activity: Top Surface (LVT Top Layer) and Bottom Surface (Pad) scored 0-1 (No Growth to <10% Growth)
4) CPSIA = Consumer Product Safety Improvement Act
5) IBC = International Building Code
Ultra-Fresh is a registered trademark of Thomson Research Associates, Inc.