Instruction Manual

Spirit II User’s Manual Section 3: Installation
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
3-17
Gas Supply Connections
Perform the following steps to connect the gas supply lines to the AGC. See Section 2
for gas supply requirements. Mating hose barbs and connectors are supplied with the
system and are sized for 3/8 inch inside diameter hose. Do not change the inlet gas
supply fittings to quick-connect fittings. Using quick-connect fittings to connect
and disconnect pressurized hoses may cause damage to the system.
Note: When making hose connections, only tighten the brass fittings enough to
make gas seals. The fittings are subject to damage if over tightened.
Air Inlet (ISO 3821 hose color - black)
Air must be supplied to the unit at all times, regardless of the cutting current or
material type.
Oxygen Inlet (ISO 3821 hose color - blue)
Oxygen must be supplied to the unit at all times, unless stainless steel is being cut
with H17 plasma.
Nitrogen Inlet (ISO 3821 hose color - black)
Nitrogen must be supplied to the unit at all times, regardless of the cutting current or
material type.
H17 Inlet (ISO 3821 hose color - red)
H17 must be supplied to the unit when stainless steel is being cut with H17 as the
plasma gas. See cutting charts in Section 5 for more information.
Argon Inlet
Argon is optional and provides improved marking capabilities. If not used, this inlet
should be capped.
32
34
31
33
35
31
32
33
34
35