Section 4: Operation with Automatic Gas Console Spirit II User’s Manual
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
4-10
Customizing Cutting or Marking Settings
Changes to any of these factory default settings will cause the Setup message at the
top of the screen to change from Setup: Optimum to Setup: Custom - Not Saved. See
the next section to save custom settings.
Altering the Current Set Point
To alter the current set point from the
default setting, press the Current
(Amps) button on the Material Screen
and choose from the list of available
values.
Note: When marking is the selected
process, the current cannot be
changed.
Altering Gas Types
On the Material Screen, press the
Plasma or Shield button and select the
desired gas type.
The plasma gas
can be changed to Air,
Oxygen, Nitrogen, or H17. Shield gas
can be changed to Air, Oxygen, or
Nitrogen.
Preflow gas cannot be changed.
Altering Gas Pressures
Normally, the preflow gas and plasma
gas pressures should not be changed.
The shield
gas can be adjusted in small
increments to fine-tune a cut. Use the
data entry button to enter a desired
pressure. Note that all of the gases
have minimum and maximum limits
and cannot be programmed beyond
these limits.