Operation Manual

Chapter 5
Advanced Configuration
54
8-Port 10/100/1000 Gigabit Switch with Webview
Cable Length This is the approximate length of the cable.
The Cable Length test can be performed only when the
port is up and operating at 1Gbps.
Admin > Save Configuration
Admin > Save Configuration
Via TFTP
After you download a new image file, the device should
be rebooted. If you are downloading a new boot image,
please follow these steps:
Download the new boot code.1.
WARNING: While inputting the boot code,
refrain from reseting the device.
Download the new software image. 2.
Reset the device now.3.
Upgrade Select this option to upgrade the switch from a
file located on a TFTP server.
TFTP Server
The TFTP Server IP Address that contains
the source file to upgrade from.
Source File Specifies the name of the upgrade file on
the TFTP server.
Backup To back up the switch configuration via TFTP,
enter the TFTP server address.
TFTP Server Specifies the TFTP Server IP Address to
which the configuration file will be saved.
Destination File Specifies the name of the
configuration file. The default is StartupCfg.cfg.
Via HTTP
This HTTP Firmware Upgrade screen is used for saving
configuration information using your web browser.
Upgrade Select this option to upgrade the switch from a
file on the local hard drive.
Source File Type in the name and path of the file or
click Browse to locate the upgrade file.
Backup
Proceed The Proceed button is used to backup the
configuration to the local hard drive.
Admin > Firmware Upgrade
Admin > FIrmware Upgrade
The Firmware Upgrade screen contains the following
fields:
via TFTP Defines the upgrade through a TFTP Server.
via HTTP Allows you to upgrade the firmware using your
Web browser.
Upgrade Defines the screen functionality as a Firmware
upgrade.
Backup Defines the screen functionality as a Firmware
backup.
TFTP Server IP Address Specifies the TFTP Server IP
Address from which files are downloaded.
Source File Name Specifies the file to be downloaded.
Destination File name Specifies the destination file
type to which to the file is downloaded. The possible field
values are:
Software Image Downloads the image file.
Boot Code Downloads the boot file.