ITEM #016887 016888 016889 016890 CONNEXXTION ® MODEL #TLEII44BNK5L TLEII44OSB5L TLEII52BNK5L TLEII52OSB5L Español p. 20 Express Assembly No Tools Required ATTACH YOUR RECEIPT HERE 4009654 Purchase Date Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-527-1292, 8:30 a.m. - 5 p.m.
TABLE OF CONTENTS Safety Information ................................................................................................................. 2 Package Contents ................................................................................................................ 4 Hardware Contents ........................................................................................................................... 5 Preparation .......................................................................
SAFETY INFORMATION WARNING To reduce the risk of fire, electrical shock or personal injury, mount fan to outlet box marked "ACCEPTABLE FOR FAN SUPPORT OF 35 LBS. OR LESS" and use mounting screws provided with the outlet box. Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
PACKAGE CONTENTS C R Y A Z B G E H D J S V U W T N F M P Q X K L I O PART A B C D E F G H I J K L M DESCRIPTION QUANTITY Downrod (preassembled) 1 Canopy (preassembled) 1 Mounting Bracket 1 Motor Housing 1 Yoke Cover (preassembled) 1 Light Kit Fitter 1 (preassembled) Blade 5 Bulb 3 Finial Plate 1 (preassembled) Blade Screw Post 15 (preassembled) Hex Nut 2 (preassembled) Lock Washer 1 (preassembled) Switch Housing Cap 1 (preassembled) IMPORTANT: You must use the parts provided with this fan fo
HARDWARE CONTENTS (shown actual size) AA BB CC Cap Three-C Clip Qty. 1 Qty. 15 + 1 extra Clip (preassembled) Qty. 6 PREPARATION Before beginning assembly of product, make sure all parts are present. Place motor on carpet or on foam to avoid damage to finish. Compare parts with package contents list and hardware contents list. If any part is missing or damaged, do not attempt to install, operate or assemble the product.
INITIAL INSTALLATION 2. Determine mounting method to use. A. Standard mount B. Angle mount 2 Note: Flushmount and closemount options are not available for this fan. A IMPORTANT: If using the angle mount, ensure the ceiling angle is not steeper than 19°. 19° max. B 3. Check to make sure blades (G) will be at least 30 inches from any obstruction. Check downrod (A) length to ensure blades (G) will be at least 7 ft. above the floor. 3 30 in. min. G 7 ft. min. 4.
INITIAL INSTALLATION 5. You may need to cut the lead wires back to simplify the wiring. If you decide to cut back the lead wires, it is suggested you do so in the following manner: 5 8 in. Take the lead wires and make sure you have pulled them all the way through the top of the downrod. Start at the TOP of the hanging ball on the downrod and measure 8 in. of lead wire, and then cut the excess wire off with wire cutters (not included).
INSTALLING SAFETY CABLE 1. Adjust safety cable (Z) length by loosening screw and nut on the safety cable vice and pulling on the cable. Adjust slack in cable to a hands length and secure vice by re-tightening screw and nut securely. The loop at the end of the safety cable (Z) should just fit over the threads on the wood screw. 1 Loop Wood Screw Vice Test safety cable (Z) by pulling on loose end of cable with pliers. If the safety cable (Z) slips, the screw and nut on the vice must be set tighter.
WIRING WARNING: To reduce the risk of fire, electrical shock or personal injury, each quick connect clip provided with this fan is designed to accept only one 12-gauge house wire and one lead wire from the fan. If your house wire is larger than 12-gauge or there is more than one house wire to connect to the corresponding fixture lead wires, consult an electrician. CAUTION: Be sure outlet box is properly grounded and that a ground (green or bare) wire is present.
WIRING 2. Wrap electrical tape (not included) around each individual clip (CC) down to the wire. 2 WARNING: Make sure no bare wire or wire strands are visible after making connections. Place green and white connections on opposite side of box from the black and blue connections. CC CC Gently push wires and clips (CC) into outlet box. CC 3. Gently slide remote control receiver (Y) flat-side up into mounting bracket (C). Turn spliced/taped wires upward and gently push wires into outlet box.
FINAL INSTALLATION 1. Raise canopy (B) toward ceiling and allow it to attach to mounting bracket (C) using the magnets mounted on each side of the mounting bracket (C). 1 C Magnet B 2. Align the preassembled blade screw posts (J) on blade arms (S) with the holes on a blade (G). Press up on the blade arm firmly so the blade screw posts (J) come through the holes in the blade (G), then slide a three-C clip (BB) onto each blade screw post (J). Repeat for each blade arm (S) and blade (G).
FINAL INSTALLATION 3. Insert the end of one blade arm (S) into the keyhole slot on the motor housing (D). Twist blade arm (S) clockwise to lock in place. 3 D Repeat with remaining blade arms (S). J S Keyhole Slot 4. Should it become necessary to remove blade arm (S) from motor housing (D), follow these steps: 4 D Remove blade arm screws (T) and washers (U) from underside of motor housing (D) and remove blade arm assembly. Remove safety screw (V) and metal tab (W) from blade arm wall.
FINAL INSTALLATION 6. Install bulbs (H). 6 CAUTION: When replacing bulb(s), allow bulb(s) and glass shade to cool down before touching. H 7. Place rubber washer (Q) inside glass shade (P) over center hole. Align hole in center of glass shade (P) with threaded rod on light kit fitter (F). Push up gently on glass shade (P) until threaded rod comes through hole. Secure glass shade (P) with hex nut (K). H 7 P CAUTION: Do NOT overtighten hex nut (K) as glass may crack or break.
INSTALLING FAN WITHOUT LIGHT KIT 1. If you do NOT wish to use the light kit, remove 3 switch housing cap screws (N) from switch housing cap (M) located on switch housing preassembled to motor housing (D). Pull down gently on switch housing cap (M). 1 D Locate wires in switch housing labeled FOR LIGHT and gently pull molex connections apart in order to disconnect switch housing cap (M) from switch housing. N Switch Housing Molex Connections M 2.
OPERATING INSTRUCTIONS CAUTION: The remote control transmitter can be programmed to multiple receivers or fans. If this is not desired, turn wall switch off to any other programmable receiver or fan. FCC Compliance Notice for Remote Control Modifications not approved by the party responsible for compliance could void the user's authority to operate the equipment. *NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
OPERATING INSTRUCTIONS 2. Restore electrical power. Within 30 seconds of restoring electrical power, press and hold the “0” button on the remote control transmitter for 5 seconds or until light on the fan blinks twice. Use the remote control transmitter to test the light and fan functions to confirm the learning process is complete. 2 NOTE: Remove protective covering from front of remote control transmitter and discard.
OPERATING INSTRUCTIONS 4a. In warmer weather, setting the reverse switch in the DOWN position will result in downward airflow creating a wind chill effect. 4a 4b 4b. In cooler weather, setting the reverse switch in the UP position will result in upward airflow that can help move stagnant, hot air off the ceiling area. 4c. IMPORTANT: Reverse switch must be set either completely UP or completely DOWN for fan to function. If the reverse switch is set in the middle position, fan will not operate.
TROUBLESHOOTING WARNING: Before beginning work, shut off the power supply to avoid electrical shock. PROBLEM Fan does not move. POSSIBLE CAUSE 1. Reverse switch not engaged. 2. Power is off or fuse is blown. 3. Faulty wire connection. Noisy operation. 1. Blades are loose. 2. Cracked blade. 3. Full range dimmer switch. 4. Fan is new. Excessive wobbling. 1. Blades are loose. 2. Blade arms incorrectly attached. 3. Unbalanced blades. 4. Fan not securely mounted.
LITEX LIFETIME LIMITED WARRANTY LITEX INDUSTRIES, LTD. warrants this fan to the original household purchaser for indoor use under the following provisions: 1-YEAR WARRANTY: LITEX INDUSTRIES, LTD. will replace or repair any fan which has faulty performance due to a defect in material or workmanship. Contact Customer Service at 1-800-527-1292 to arrange for return of fan. Return fan, shipping prepaid, to Litex Industries, Ltd.