Installation Guide

LDN6” –7”hole
LDN4” –4-3/4”hole
Cut ceiling opening slightly larger than the
outside diameter on the mounting frame.
4” Ceiling opening: 4-3/4” (12.1cm). 6”
Ceiling opening: 7” (17.8cm)
C) Lay-in Panel T-bar Ceiling Installation
CJ5201053 Rev D
Page 3
© Acuity Brands Lighting, Inc. 2016
All Rights Reserved.
B) Important Safety Information - For Your Protection, Read Carefully
Warning: Risk offire. Donot install insulation within 3 inches of fixture sides or wiring compartment, nor above fixture in such a manner
as to entrapheat.
Electriccurrentcan cause painful shockor seriousinjury unless handledproperly. For your safety, always rememberthe following:
Turn off thesupply power.
Groundthe fixture to avoid potential electrical shocks.
Do not handle an energized fixture or energize any fixture with wet hands, when standing on a wet or damp surface, or in
water.
1
5
2
Adjust channel bars to the correct spacing
between T-bar. See Page 4 for procedure
for non-accessible ceiling installation.
3
4 6
Assemble the channel bars to each side of the
of the mounting frame with the included
hardware. Leave the hardware loose to adjust
the position of the frame in the ceiling.
Position mounting frame through opening
in ceiling.
Secure channel bars to T-bar by means of
wire ties.
Lithonia Lighting
1400 Lester Road Conyers Georgia 30012
P 800 315 4935 F 770 860 3129
www.Lithonia.com
Adjust the mounting frame vertically to
align the bottom edge of the draw-down
to either flush or slightly above the ceiling
line.
Ceiling Line
Mounting Frame
Draw-down