Brochure

Table Of Contents
© 2017 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 03/03/17
Radial Lead Fuses
TE5
®
> Time-Lag Fuse > 369 Series
RoHS
Pb
Amp
Code
Amp
Rating
(A)
Voltage
Rating
(V)
Breaking
Capacity
Nominal
Cold
Resistance
(Ohms)
Voltage
Drop
1.0 × I
N
max. (mV)
Power
Dissipation
1.5 × I
N
max. (mW)
Melting
Integral
10 × I
N
max. (A
2
s)
Agency Approvals
PS
E
0800 0.800 300
50A
@300VAC
0.0960 110 280 5.1200
x
110 0 1. 0 0 300 0.0715 115 400 8.0000 x x x x
116 0 1.60 300 0.0400 95 600 18.4320 x x x x
1200 2.00 300 0.0298 90 700 29.0000 x x x x
1315 3.15 300 0.0170 80 110 0 78.3880 x x x x
1400 4.00 300 0.0128 75 1200 126.4000 x x x x
1500 5.00 300 0.0101 70 1000 106.2500 x x x x
1630 6.30 300 0.0077 65 1200 160.7400 x x x
Electrical Characteristics
PS
E
Application testing is strongly recommended.
369 Series, TE5
®
Time-Lag Fuse
Agency Agency File Number Ampere Range
E67006 0.800A - 6.3A
PS
E
JET 1896-31007-2002 1A - 5A
1605793 1A - 6.3A
40037351
1A, 1.6A - 2A,
3.15A - 6.3A
Electrical Characteristics
Halogen free, Lead-free
and RoHS compliant
Reduced PCB space
requirements
Direct solderable or
plug-in versions
Internationally approved
Low internal resistance
Shock safe casing
Vibration resistant
% of Ampere
Rating
Opening Time
150% 1 Hour, Minimum
210% 120 sec., Maximum
275% 400 ms., Min.; 10 sec., Max.
400% 150 ms., Min.;, 3 sec., Max.
1000%
20 ms., Min.; 150 ms., Max.
Applications
The 369 Series are TE5
®
Time-Lag Fuses, 300V rated and
designed in accordance to IEC 60127-3.
Electronic Ballast
Description
Features
Agency Approvals
Note:
1. Resistance is measured at 10% of rated current, 25°C.
Additional Information
Datasheet
Samples
Resources