Brochure

Table Of Contents
© 2017 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 03/03/17
Axial Lead & Cartridge Fuses
5×20 mm > Fast-Acting > 216 Series
Amp
Code
Amp
Rating
(A)
Voltage
Rating
(V)
Interrupting
Rating
Nominal
Cold
Resistance
(Ohms)
Nominal
Melting
I
2
t (A
2
sec)
Maximum
Voltage
Drop at
Rated
Current
(mV)
Maximum
Power
Dissapation
at 1.5ln
(W)
Agency Approvals
PS
E
.050 0.05 250
1500A@
250Vac
15.9000 0.00019 10000 1. 6 x x x x x x
.063 0.063 250 10.4500 0.00079 8800 1. 6 x x x x x x
.080 0.08 250 7.8850 0.00084 7600 1. 6 x x x x x x
.10 0 0.1 250 5.7925 0.00450 7000 1. 6 x x x x x x
.125 0.125 250 3.6750 0.00546 5000 1. 6 x x x x x x
.160 0.16 250 5.3490 0.00326 4300 1.6 x x x x x x
.200 0.2 250 3.3500 0.00439 3500 1. 6 x x x x x x
.250 0.25 250 2.3500 0.01350 2800 2.5 x x x x x x
.315 0.315 250 1.8500 0.02320 2500 2.5 x x x x x x
.500 0.5 250 0.8660 0.16500 1800 2.5 x x x x x x
.630 0.63 250 0.4650 0.05940 1500 2.5 x x x x x x
.800 0.8 250 0.2950 0.14600 1200 2.5 x x x x x x
0 01. 1 250 0.2370 0.18000 1000 2.5 x x x x x x x x x
1.25 1.25 250 0.1530 0.48000 800 4 x x x x x x x x x
01. 6 1. 6 250 0 .1112 1.00500 600 4 x x x x x x x x x
002. 2 250 0.0764 1.87000 500 4 x x x x x x x x x
02.5 2.5 250 0.0584 3.67200 400 4 x x x x x x x x x
3.15 3.15 250 0.0368 6.70000 350 4 x x x x x x x x x
004. 4 250 0.0247 14.99500 300 4 x x x x x x x x x
005. 5 250 0.0183 27.46000 250 4 x x x x x x x x x
06.3 6.3 250 0.0137 56.43000 200 4 x x x x x x x x x
008. 8 250 0.0123 64.31500 200 4 x x x x x x* x x
010. 10 250 0.0079 154.34000 200 4 x x x x x x* x x
12.5 12.5 250 0.0057 175.00000 200 N/A** x x x x* x x
016. 16 250
750A@
250Vac
0.0040 462.50000 200 N/A** x x x x x x
Electrical Characteristics Specifications by Item
Average Time Current Curves
Temperature Re-rating Curve
CURRENT IN AMPERES
0.001
0.01
0.1
0.01
0.1 110
100 1000
1
10
100
1000
10000
TIME IN SECONDS
0.050A
0.063A
0.080A
0.100A
0.125A
0.160A
0.200A
0.250A
0.315A
0.500A
1A
0.800A
0.630A
1.25A
1.6A
2A
2.5A
3.15A
4A
5A
6.3A
8A
10A
12.5A
16A
* Approval for cartidge versions only.
N/A** - Please contact Littelfuse for details on these parameters
I
2
t test at 10x rated current
Note: Rerating depicted in this curve is in addition to the standard derating of 25% for
continuous operation.