Surface Mount Fuses
Ceramic Fuse > 501 Series
501 Series – High Current 1206 Fast-Acting Fuse
Description
The 501 Series is a 100% Lead-free, RoHS compliant and
Halogen-free fuse series designed specifically to provide
over- current protection to circuits that operate under high
working ambient temperature up to 150°C.
The general design ensures excellent temperature stability
and performance reliability.
The high I
2
t values which is typical in the Littelfuse
Ceramic Fuse family, ensure high inrush current withstand
capability.
Agency Approvals
AGENCY AGENCY FILE NUMBER AMPERE RANGE
E10480 10A - 20A
29862 10A - 20A
Features
Operating Temperature
from -55ºC to +150ºC
Designed to provide
over-current protection
in high current voltage
regulator module (VRM)
applications
100% Lead-free, RoHS
compliant and Halogen-
free
Suitable for both leaded
and lead-free reflow /
wave soldering
Electrical Characteristics for Series
% of Ampere
Rating
Ampere Rating Opening Time at 25ºC
100% 10A – 20A 4 Hours, Minimum
350% 10A – 20A 5 Seconds, Maximum
Applications
RoHS
Pb
Voltage Regulator
Module (VRM)
Equipment
Notebook PC
DC-DC Converter
Ampere
Rating
(A)
Amp
Code
Max. Voltage
Rating
(V)
Interrupting
Rating
(DC)
1
Nominal
Resistance
(Ohms)
2
Nominal
Melting I
2
T
(A
2
Sec.)
3
Nominal Voltage
Drop At Rated
Current (V)
4
Nominal Power
Dissipation At
Rated Current (W)
Agency Approvals
10 010. 32
150 A @ 32 VDC
0.00362 10.385 0.04407 0.4407 x x
12 012. 32 0.00311 20.341 0.04927 0.5912 x x
15 015. 32 0.00250 39.700 0.04843 0.7265 x x
20 020. 32 0.00194 86.360 0.05888 1.1776 x x
Electrical Specifications by Item
Notes:
1. DC Interrupting Rating tested at rated voltage with time constant < 0.5 msec.
2. Nominal Resistance measured with < 10% rated current.
3. Nominal Melting I
2
t measured at 1 msec. opening time. For other I
2
t data refer to chart.
4. Nominal Voltage Drop measured at rated current after temperature has stabilized and
with fuse mounted on board with 3-oz Cu trace.
Devices designed to carry rated current for 4 hours minimum. It is recommended that
devices be operated continuously at no more than 80% rated current. See “Temperature
Re-rating Curve”for additional re-rating information.