Special Application Fuses
PICO
®
259-UL913 Series Intrinsically Safe Fuse for Hazardous Locations
PICO
®
259-UL913 Series Intrinsically Safe Fuse
Description
Agency Approvals
Agency Agency File Number Ampere Range
Baseefa02ATEX0071U 0.62A - 5A
E10480
E358130
0.62A - 5A
IECEx BAS 10.0098U 0.62A - 5A
Electrical Characteristics for Series
Features
Applications
% of Ampere
Rating
Opening Time
100% 4 Hours, Minimum
200% 5 Seconds, Maximum
Encapsulated and sealed
(1mm minimum)
0.62A - 5A range options
Designed to operate
within hazardous
environments
Global hazardous location
certifications
Electrical Specifications by Items
Schedule of limitations:
1) The fuse must be mounted in such a way that creepage and clearance distances aren’t
impaired in any way.
2) The fuse is suitable for use in intrinsically safe equipment for voltages not exceeding
190V peak.
3) Maximum surface temperature rise at 170% rated current: ≤750mA=40ºC, 1A=55ºC,
3A=118ºC and 5A=135ºC.
The 259-UL913 Series offers a range of encapsulated fuses
certified under the UL 913, the standard for intrinsically safe
electrical equipment, to operate in hazardous locations. Ideal for
use in the oil, gas, mine, chemical process, and pharmaceutical
industries, the 259-UL913 fuse was designed to limit the energy
and temperature generated during its operation. In addition
to UL913, these fuses meet ATEX and IECEx requirements.
The fuse design and its encapsulant are suitable for use in
intrinsically safe appartatus and associated apparatus for voltage
not exceeding 125V rms (190V peak).
Testing, measuring or processing electronic and
electrical equipment
Additional Information
Datasheet
Samples
Resources
RoHS
Reference Standards
Agency Standards
ATEX
EN 60079-0, EN 60079-11
IECEx
IEC 60079-0, IEC 60079-11
Ampere
Rating
(A)
Amp
Code
Interrupting
Rating
Nominal
Melting
I
2
t (A
2
Sec.)
Minimum Cold
Resistance at
-20°C (Ohms)
Minimum Cold
Resistance at
-40°C (Ohms)
Nominal Cold
Resistance at
25°C (Ohms)
Agency Approvals
0.062 .062
50A @ 125 VAC
300A @ 125 VDC
0.00011 4.89 4.39 7. 0 0 x x x
0.125 .125 0.0012 1.35 1.26 1.70 x x x
0.250 .250 0.0095 0.51 0.48 0.67 x x x
0.375 .375 0.025 0.32 0.29 0.395 x x x
0.500 .500 0.0598 0.24 0.22 0.302 x x x
0.750 .750 0.153 0.14 0.12 0.175 x x x
1. 0 0 0 01. 0.256 0.10 0.07 0.128 x x x
3.00 003. 1.27 0.03 0.01 0.03 x x x
5.00 005.
50A @ 125 VAC
300A @ 63 VDC
4.14 0.01 0.005 0.0158 x x x
Application testing is strongly recommended.