8,5
0,5 min
max. 8L
0,6
5,08
1 +0,1
40mA 0040 250V 900 100 0.0002
50mA 0050 250V 320 80 0.00035
63mA 0063 250V 350 100 0.0005
80mA 0080 250V 370 120 0.0014
100mA 0100 250V 600 130 0.0038
125mA 0125 250V 550 172 0.0066
160mA 0160 250V 500 165 0.014
200mA 0200 250V 465 190 0.03
250mA 0250 250V 400 250 0.051
315mA 0315 250V 380 250 0.1
400mA 0400 250V 120 135 0.025
500mA 0500 250V 120 155 0.042
630mA 0630 250V 115 200 0.076
800mA 0800 250V 120 310 0.12
1.00A 1100 250V 110 310 0.2
1.25A 1125 250V 100 360 0.31
1.60A 1160 250V 100 600 0.53
2.00A 1200 250V 85 500 0.98
2.50A 1250 250V 80 660 1.8
3.15A 1315 250V 90 950 3.1
4.00A 1400 250V 80 920 6.7
5.00A 1500 250V 80 1000 12.00
6.30A* 1630 250V 70 1200 24.00 G
VDE
SEMKO
cURus
METI-T-
Mark
CCC
35 A / 250 V AC
1
50-60 Hz
cos
ϕ
= 1.0
40 A / 250 V AC
VDE
50 A / 250 V AC
SS
SS
S
UBMINIAUBMINIA
UBMINIAUBMINIA
UBMINIA
TURETURE
TURETURE
TURE
F F
F F
F
USESUSES
USESUSES
USES
Dimensions (mm)Dimensions (mm)
Dimensions (mm)Dimensions (mm)
Dimensions (mm)
Long Leads (L=18.8mm)
Short Leads (L=4.3mm)
Limits for Pre-arcing TimeLimits for Pre-arcing Time
Limits for Pre-arcing TimeLimits for Pre-arcing Time
Limits for Pre-arcing Time
Permissible continuous operating current is Permissible continuous operating current is
Permissible continuous operating current is Permissible continuous operating current is
Permissible continuous operating current is
100 100
100 100
100
% at ambient temperature of 23% at ambient temperature of 23
% at ambient temperature of 23% at ambient temperature of 23
% at ambient temperature of 23
ºC (73.4ºC (73.4
ºC (73.4ºC (73.4
ºC (73.4
ºF).ºF).
ºF).ºF).
ºF).
1
Per UL, approved breaking capacity is 50 A at 250 V. * Conducting path min. 0.2 mm
2
Holes in PCB
SpecificationsSpecifications
SpecificationsSpecifications
Specifications
PackagingPackaging
PackagingPackaging
Packaging
000: Tape/Ammopack (1000 pcs.)
041: Short Leads - Bulk (1000 pcs.)
MaterialsMaterials
MaterialsMaterials
Materials
Base/Cap: Brown Thermoplastic
Polyamide PA 6.6, UL 94 V0
Round Pins: Copper, Sn plated
Operating TOperating T
Operating TOperating T
Operating T
emperatureemperature
emperatureemperature
emperature
-40 ºC to +85 ºC (consider de-rating)
Climatic CategoryClimatic Category
Climatic CategoryClimatic Category
Climatic Category
-40 ºC/+85 ºC/21 days
(IEC 60068-1,-2-1,-2-2,-2-78)
Stock ConditionsStock Conditions
Stock ConditionsStock Conditions
Stock Conditions
+10 ºC to +60 ºC
relative humidity 75 % yearly average,
without dew, maximum value for 30 days-95 %
Vibration ResistanceVibration Resistance
Vibration ResistanceVibration Resistance
Vibration Resistance
24 cycles at 15 min. each (EN 60068-6)
10 - 60 Hz at 0.75 mm amplitude
60 - 2000 Hz at 10 g acceleration
Lead Pull StrengthLead Pull Strength
Lead Pull StrengthLead Pull Strength
Lead Pull Strength
10 N (EN 60068-2-21)
SolderabilitySolderability
SolderabilitySolderability
Solderability
260 ºC, 3 s (Wave)
350 ºC, 3 s (Soldering iron)
Soldering Heat ResistanceSoldering Heat Resistance
Soldering Heat ResistanceSoldering Heat Resistance
Soldering Heat Resistance
260 ºC, 10 s (IEC 60068-2-20)
MarkingMarking
MarkingMarking
Marking
, 370, 250 V, F, Current Rating, Approvals
Unit WeightUnit Weight
Unit WeightUnit Weight
Unit Weight
0.77 g (approx.)
OrderOrder
OrderOrder
Order
Qty.Qty.
Qty.Qty.
Qty.
Order-Order-
Order-Order-
Order-
SeriesSeries
SeriesSeries
Series
Amp Code PackagingAmp Code Packaging
Amp Code PackagingAmp Code Packaging
Amp Code Packaging
InformationInformation
InformationInformation
Information
Number Number
Number Number
Number
370
Rated Amp Voltage Breaking Voltage Drop Power Dissipation Melting Integral Approvals
Current Code Rating Capacity 1.0 x I
N
1.5 x I
N
10 x I
N
max. (mV) max. (mW) max. (A
2
s)
IEC 60127-3/III, 250 VIEC 60127-3/III, 250 V
IEC 60127-3/III, 250 VIEC 60127-3/III, 250 V
IEC 60127-3/III, 250 V
, F, F
, F, F
, F
TT
TT
T
ime-Current Characteristicime-Current Characteristic
ime-Current Characteristicime-Current Characteristic
ime-Current Characteristic
Quick Acting (F)
StandardStandard
StandardStandard
Standard
IEC 60127-3/III
ApprovalsApprovals
ApprovalsApprovals
Approvals
VDE
SEMKO
cULus Recognized
METI
CCC
FeaturesFeatures
FeaturesFeatures
Features
Reduced PCB space requirements
Direct solderable or plug-in versions
Internationally approved
Low internal resistance
Shocksafe casing
Vibration resistant
Halogen free
WW
WW
W
ebLinksebLinks
ebLinksebLinks
ebLinks
Further infos see:Further infos see:
Further infos see:Further infos see:
Further infos see:
www.wickmanngroup.com
Further application infos seeFurther application infos see
Further application infos seeFurther application infos see
Further application infos see
Fuseology:Fuseology:
Fuseology:Fuseology:
Fuseology:
www.wickmanngroup.com/download/
fuseology.pdf
Rated Current 1.5 x I
N
2.1 x I
N
2.75 x I
N
4 x I
N
10 x I
N
40 mA ... 6.30 A > 1h < 30 min 10 ms ... 3 s 3 ms ... 300 ms <20 ms
No.No.
No.No.
No.
370 / 370 /
370 / 370 /
370 /
TR5TR5
TR5TR5
TR5
®®
®®
®