Installation

120V,7W
A
B
C
D
E
F
G
H
ASSEMBLING & INSTALLATION INSTRUCTIONS PRODUCT#
8555 8573 8574 8575 8576
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER .
Fig.1
ASSEMBLING THE FIXTURE (Fig.2).
1. Return the arms to suitable position.
2. Attach the pipe nipple with the hex nut(D) to the top coupling of the
fixture body(E) and securely tighten..
3. Attach the crown(C) over end pipe nipple of the fixture body (E) and
lock it with the lamellar nut(B). Attach the loop(A) to the end pipe nipple
by turning it clockwise until tight.
4. Place the glass shade (G) onto the socket of the fixture body (E) and
lock it with the screw shell (F) securely tighten.
5. Raise the harp(J) to the bottom end of screw protruding and lock it with
the ball nut(I).Raise the light bulb(H 120V 7W) to the bottom socket
of the fixture body(E),this is light bulb including.Raise the glass(K)
and cover(L) to the bottom end of pipe nipple protrudent and lock
it with the hex nut(M),attach the cover(N) to the glass(K) and lock
it with the finial(O).
6. Install the light bulbs(no including) in accordance with the fixture
specifications.NOTE: DO NOT EXCEED THE SPECIFIED
WATTAGE!
HANGING THE FIXTURE (Fig.1)
1. Shut off the power at the circuit breaker and remove old fixture from
ceiling, including the old single bar.
2. Carefully unpack new fixture and lay all the parts on a clear surface.
3. Thread nipple (C) into loop (F) until snug.
4. Thread other end of nipple (C) with loop attached into single bar (D) until
snug.
5. Place lock washer (B) over end of nipple protruding through single bar
and thread hex nut (A) onto nipple until tight.
6. Take this single bar assembly and mount to ceiling junction box with
junction box screws (E). Tighten screws securely with screwdriver.
7. Using proper chain pliers to open one end link of the chain provided and
connect to the fixture loop (I). Close the link.
8. By measuring, determine correct number of links needed for proper
hanging height. Using proper chain pliers disconnect and discard
remaining chain.
9. Lace the fixture wires through the chain.
10. Slip loop collar (H) over the chain, then do the same with the canopy (G).
11. Open the other end link of the chain and hang the fixture on the loop at the
ceiling. Close the link.
12. Feed the fixture wires through the loop (F) and nipple (C) and pull until
taut.
13. Slide canopy (G) up flush to ceiling, secure using loop (H).
CONNECTING THE WIRES (Fig.3)
1. Take the black wire from the ceiling junction box and the smooth wire leg
from the fixture and twist bare ends together. Twist wire connector onto
end of wire until snug.
2. Repeat same process with white junction box wire and ribbed wire leg of
fixture wire. NOTE: Twist wires together in the same direction you twist
the wire connector onto wires.
3. If your junction box has a grounding wire (green or bare copper), attach
this wire and the bare copper wire from the fixture together as step 1.If
junction box has no ground wire, attach the bare copper fixture wire to the
green ground screw on the single bar.
4. Tuck these wire connections neatly into the ceiling outlet box and then
raise the canopy (G) all the way to the ceiling. Raise the loop (H) and
thread onto ceiling loop protruding through canopy.
Your installation is now complete. Return power to the junction
box and test the fixture.
Fig.2
Fig.3
White or
HOUSE
Black
WIRES
(Hot)
Smooth
FIXTURE
WIRES
Black or
Ribbed
WIRES
FIXTURE
Bare Copper(Ground)
FIXTURE
WIRES
Copper
(Ground)
HOUSE
(Neutral)
WIRES
White
Bare
Green or
WIRES
HOUSE
I
H
CHAIN
G
F
E
D
A
B
C
Junction
Box(Ceiling)

Summary of content (1 pages)