Operation Manual

40
CAUTION
When equipment requiring a large starting power, like a motor etc., is used,
the overload indicator light (red) and the output indicator light (green) may
light together for a short time (about 4 sec), but this is no abnormality.
After start of the equipment, the overload indicator light (red) will go out and
the output indicator light (green) will stay lit.
The DC receptacle may be used for charging 12 volt automotive-type batteries
only.
NOTE: In DC operation, turn the Smart throttle switch to the OFF position.
1.Connect the charging cables to the DC receptacle of the generator and then to
the battery terminals.
WARNING
To prevent the possibility of creating a spark near the battery, connect
charging cable first to the generator, then to the battery. Disconnect cable
first at the battery.
Before connecting charging cables to a battery that is installed in a vehicle,
disconnect the vehicles grounded battery cable. Reconnect the vehicle's
grounded battery cable after the charging cables are removed. This
procedure will prevent the possibility of a short circuit and sparks if you make