Operation Manual

49
The gap should be 0.6-0.7 mm (0.024-0.028in). Correct as necessary by
carefully bending the side electrode.
7.lnstall the spark plug carefully, by hand, to avoid cross-threading.
8.After a new spark plug has been seated by hand, it should be tightened 1/2
turn with a wrench to compress its washer.
If a used plug is being reinstalled, it should only require 1/8 to 1/4 turn after
being seated.
9.Reinstall the spark plug cap on the spark plug securely.
10.Reinstall the spark plug maintenance cover.
CAUTION
The spark plug must be securely tightened. An improperly tightened plug can
become very hot and possibly damage the generator.
Never use a spark plug with an improper heat range.
4. SPARK ARRESTER MAINTENANCE (equipped type only)
WARNING: If the generator has been running, the muffler will be very hot. Allow
it to cool betore proceeding.
CAUTION: The spark arrester must be serviced every 100 hours to maintain its
efficiency.
1.Remove the four 5 mm screws, and remove the muffier protector.