CAUTION
Confirm that the use equipment to be connected is switched off.
When the equipment to be used is switched on, it will operate suddenly, and
injuries or accidents may be caused.
4.Switch on the equipment to be used.
In case of overload operation or when trouble occurs for the equipment being
used, the output indicator light (green) will go out, the overload indicator light
(red) will light continuously, and no power will be put out.
At this time, the engine will not stop, so that the engine must be stopped by
setting the respective engine switch to STOP.
CAUTION
When equipment requiring a large starting power, like a motor etc., is used,
the overload indicator light (red) and the output indicator light (green) may
light together for a short time (about 4 sec), but this is no abnormality.
After start of the equipment, the overload indicator light (red) will go out and
the output indicator light (green) will stay lit.
The DC receptacle may be used for charging 12 volt automotive-type batteries
only.
NOTE: In DC operation, turn the Smart throttle switch to the OFF position (only
75034 and 75035).
1.Connect the charging cables to the DC receptacle of the generator and then to
the battery terminals.
WARNING
To prevent the possibility of creating a spark near the battery, connect
charging cable first to the generator, then to the battery. Disconnect cable
first at the battery.
Before connecting charging cables to a battery that is installed in a vehicle,
disconnect the vehicles grounded battery cable. Reconnect the vehicle's
grounded battery cable after the charging cables are removed. This
procedure will prevent the possibility of a short circuit and sparks if you make
accidental contact between a battery terminal and the vehicle's frame or
body.
CAUTION
Do not attempt to start an automobile engine with the generator still
connected to the battery. The generator may be damaged.
Connect the positive battery terminal to the positive charging cord. Do not
reverse the charging cables, or serious damage to the generator and/or
battery may occur.
WARNING