Service Manual

1 Service
8
General Operation
How the water heater operates
The Armor water heater uses an advanced stainless steel heat
exchanger and an electronic control module that allows fully
condensing operation. The blower pulls in gas and air and
pushes flue products out of the water heater through the heat
exchanger and flue piping. The control module regulates blower
speed to control water heater firing rate. The gas valve senses
the amount of air flowing into the water heater and allows only
the right amount of gas to flow.
Sequence of operation
Table 1A shows control module normal sequences of operation
for water heating operation.
Access modes
User
The user can adjust tank target temperatures by pressing the
NAVIGATION dial when “SETPOINTS” is flashing at the
bottom of the display. The date and time, and the temperature
units can also be changed.
Installer
Most parameters are available only to the installer, accessible by
entering the installer password (5309).
Saving parameters (reference the Parameter Table -
Table 1D on pages 12 and 13 of this manual)
Please note that the brackets ([]) denote
screen status.
NOTICE
To save parameters and exit programming:
Press the RIGHT SELECT [SAVE] key and then press the
RIGHT SELECT [HOME] key.
To enter a parameter and continue programming:
Press the RIGHT SELECT [SAVE] key 1 time to return to the
parameter listings; press again to return to the menu listings.
Remember to press the RIGHT SELECT [HOME] key when
finished programming in order to save the changes made.
Service Manual