1 Maintenance schedule
5
User’s Information Manual
Service technician
(Refer to the Copper-Fin Installation and
Service manual)
General:
• Address reported problems
• Inspect interior; clean and vacuum if
necessary;
• Check for leaks (water, gas, flue)
• Examine venting system
• Check system water pressure/
system piping/expansion tank
• Check control settings
• Check wiring connections
• Flame inspection (stable, uniform)
• Check flue gas passageways
• Inspect and clean the burner
• Perform start-up check-out and
performance verification. Refer to
the Startup section in the Copper-
Fin Installation and Service manual
If combustion or performance
indicate need:
• Clean heat exchanger
• Remove and wash burner
Annual Startup
Owner maintenance
Daily
• Check appliance area
• Check pressure/temperature
gauge
Monthly
• Check vent piping
• Check relief valve
Periodically
• Test low water cutoff (if used)
• Reset button (low water cutoff)
Every
6 months
• Check appliance piping (gas and
water) for leaks
• Operate relief valve
End
of season
months
• Shut appliance down (unless
boiler used for domestic hot
water)