Submittal Sheet

KNIGHT
®
WALL MOUNT HEATING BOILERS
KNIGHT Wall Mount
HEATING BOILER
Submittal Sheet
WHN-Sub-02
JOB NAME ______________________________________________________________________
LOCATION ______________________________________________________________________
ENGINEER____________________________________________________________________
WHOLESALER __________________________________________________________________
MECH. CONTRACTOR ___________________________________________________________
MODEL NO. _____________________________________________________________________
TYPE GAS ______________________________________________________________________
Btu/hr INPUT_____________________________________________________________________
Btu/hr OUTPUT___________________________________________________________________
NOTES
Smart System
Features
> SMART SYSTEM Digital Operating Control
> Multi-Colored Graphic LCD Display
with Navigation Dial and Soft Keys
> Three Boiler Setpoint Temperature Inputs
> Plus Domestic Hot Water Prioritization
> Built-in Cascading Sequencer for up to 8 Boilers
> Multiple Size Boiler Cascade
> Lead Lag
> Efficiency Optimization
> Front End Loading Capability with Copper Fin II
>
Outdoor Reset Control with Outdoor Air Sensor
> Programmable for Three Reset Temperature Inputs
> Programmable System Efficiency Optimizers
> Night Setback
> DHW Night Setback*
> Anti-Cycling
> Outdoor Air Reset Curve
> Ramp Delay
> Boost Temperature & Time
> Three Pump Control
> System Pump with Parameter for Continuous Operation
> Boiler Pump with Variable Speed Pump Control*
> Domestic Hot Water Pump
> Domestic Hot Water Prioritization
> DHW tank piped with priority in the boiler loop
> DHW tank piped as a zone in the system with the pumps
controlled by the Smart System
> DHW Modulation Limiting
> Separately Adjustable Space Heat/DHW Switching Times*
> Building Management System Integration
> 0-10 VDC Input to Control Modulation or Set Point
> 0-10 VDC Modulation Rate Output
> 0-10 VDC Input to Enable/Disable call for heat
> Access to BMS Settings through Graphic LCD Display
> High-Voltage Terminal Strip
> 120 VAC / 60 Hertz / 1 Phase Power Supply
> Three Sets of Pump Contacts
> Low Voltage Terminal Strip
> 24 VAC Device Relay
> Proving Switch Contacts
> Flow Switch Contacts
> Alarm on Any Failure Contacts
> Runtime Contacts
> DHW Thermostat Contacts
> 3 Space Heat Thermostat Contacts
> System Sensor Contacts
> DHW Tank Sensor Contacts
> Outdoor Air Sensor Contacts
> Cascade Contacts
> 0-10 VDC BMS External Control Contact
> 0-10 VDC Boiler Rate Output Contacts
> 0-10 VDC Variable Speed System Pump Signal Input*
> 0-10 VDC Signal to Control Variable Speed Boiler Pump*
> Modbus Contacts
> Time Clock
> Data Logging
> Hours Running, Space Heating
> Hours Running, Domestic Hot Water
> Ignition Attempts
> Last 10 Lockouts
> Maintenance Reminder
> Custom Maintenance Reminder with
Contractor Contact Information
> Installer Ability to De-activate Service Reminder
> Low-Water Flow Safety Control & Indication
> Password Security
> Customizable Freeze Protection Parameters
Standard Features
> ENERGY STAR Most Efficient Recognition
§
> 95% DOE AFUE Efficiency
> Modulating Burner with 5:1 Turndown
> Direct-Spark Ignition
> Low-NOx Operation
> Field Convertible from Natural to LP Gas
> ASME Stainless Steel Heat Exchanger
> 30 psi ASME Relief Valve
> Vertical & Horizontal Direct-Vent
> PVC, CPVC, Polypropylene or SS Venting up to 100 feet
> Smart System Control
> Condensate Trap
> Other Features
> Automatic Reset High Limit
> Adjustable High Limit w/Manual Reset
> Boiler Circulating Pump
> Wall-Mount Bracket
> Zero Clearances to Combustible Materials
> 12-Year Limited Warranty
(See Warranty for Details)
Optional Equipment
Modbus Communication
Flow Switch
Low-Water Cutoff w/Manual Reset & Test
Alarm Bell
Concentric Vent Kit
SMART SYSTEM PC Software
BMS Gateway to LON or BacNet
Multi-Temperature Loop Contro
Sidewall Vent Termination
Firing Codes
> M9 Standard Construction
> M7 California Code
* Exclusive feature, available only from Lochinvar
§ WHN 55-285 only

Summary of content (2 pages)