Installation Instructions

Tools Typically Required
Kraft paper or other material to protect surrounding area.
Safety Precautions:
Well-ventilated area, wash hands after use.
Preparation:
For best performance, the adhesive and materials should be between 56°F (13°C) and 95°F (35°C). Shake can well before using
(10-12 times). Surfaces must be clean, dry and free of foreign materials. Protect finished surfaces. Pre-fit all materials. Testing of
substrates for compatibility is recommended. Repositioning is not possible. Turn spray tip so that the black dot is aligned with the
nozzle.
Application:
Hold can in a vertical position. Point valve towards surface and spray from a distance of 8 to 10 (20 to 25 cm). Keep the can
moving to create an even coat and avoid build-up on the surface. Start and stop the spray just off the work to prevent runs and sags.
Apply an even coat to both surfaces to be bonded and allow to dry 2 to 5 minutes between coats. Apply maximum pressure over
entire surface. Adhesive loses tack after approximately 10 minutes. Recoat if time exceeded. Porous surfaces will require more than
one coat.
As an adhesive primer for building weatherization systems (house wraps and flashing tapes): The adhesive can be stored during
cold weather application for up to 30 minutes at 0°F (-18°C) before spraying. Apply one coat of the adhesive to one surface (i.e.
OSB or house wrap) and immediately apply the adhesive surface of the flashing tape to the primed surface after approximately 10
seconds and apply pressure.
Clean-up:
After use, invert spray can and spray for approximately 2 seconds (or until spray is free of adhesive) to clear valve and spray tip.
Clean spray tip with turpentine or mineral spirits. Note: When using solvents for cleanup, use proper precautionary measure.