SDS

IDH number: 2082702
Product name: Loctite Power Grab All Purpose Paneling & FRP Adhesive
Page 3 of 6
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Employers should complete an assessment of all workplaces to determine the need for, and selection of, proper exposure
controls and protective equipment for each task performed.
Hazardous Component(s)
ACGIH TLV
OSHA PEL
AIHA WEEL
OTHER
Limestone
10 mg/m3 TWA Total
dust.
5 mg/m3 PEL
Respirable fraction.
15 mg/m3 PEL Total
dust.
None
None
Quartz (SiO2)
0.025 mg/m3 TWA
Respirable fraction.
2.4 MPPCF TWA
Respirable.
0.1 mg/m3 TWA
Respirable.
0.3 mg/m3 TWA Total
dust.
None
None
Engineering controls:
Provide local and general exhaust ventilation to effectively remove and
prevent buildup of any vapors or mists generated from the handling of this
product.
Respiratory protection:
If ventilation is not sufficient to effectively prevent buildup of aerosols, mists or
vapors, appropriate NIOSH/MSHA respiratory protection must be provided.
Eye/face protection:
Safety goggles or safety glasses with side shields.
Skin protection:
Use impermeable gloves and protective clothing as necessary to prevent skin
contact.
9. PHYSICAL AND CHEMICAL PROPERTIES
Physical state:
Liquid
Color:
White
Odor:
Acrylic
Odor threshold:
Not available.
pH:
7.3 - 8.5
Vapor pressure:
17.5 mbar (20 °C (68°F)) no method
Boiling point/range:
> 100 °C (> 212°F)
Melting point/ range:
Not available.
Specific gravity:
1.3
Vapor density:
Heavier than air, (Air = 1)
Flash point:
> 93.3 °C (> 199.94 °F) no method
Flammable/Explosive limits - lower:
Not available.
Flammable/Explosive limits - upper:
Not available.
Autoignition temperature:
Not available.
Evaporation rate:
0.3 (Butyl acetate = 1)
Solubility in water:
Soluble
Partition coefficient (n-octanol/water):
Not available.
VOC content:
0.1 %; 14 g/l (by weight, calculated using CARB method; g/L less water, less
exempts calculated using SCAQMD method)
Viscosity:
0 - 1,000,000 cp
Decomposition temperature: