SDS

IDH number: 2899405
Product name: Loctite PL Polyurethane Roof and Flashing Sealant
Page 2 of 6
Phthalic acid, di(C9-11)alkylester,
branched, C10-rich
68515-49-1
>= 20 - <= 30
Xylenes
1330-20-7
>= 1 - <= 5
Carbon black
1333-86-4
>= 0.1 - <= 1
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
4. FIRST AID MEASURES
Inhalation:
If not breathing, give artificial respiration. If breathing is difficult, oxygen
should be administered by qualified personnel. Move to fresh air. If symptoms
persist, seek medical advice.
Skin contact:
Rinse with running water and soap. Remove contaminated clothing and
shoes. Seek medical attention immediately. Wash contaminated clothing
before reuse. Thoroughly clean shoes before reuse. Discard any shoes or
clothing items that cannot be decontaminated.
Eye contact:
Rinse immediately with plenty of water, also under the eyelids, for at least 15
minutes. Seek medical attention immediately.
Ingestion:
Seek immediate medical attention. Do not induce vomiting. Never give
anything by mouth to an unconscious person.
Symptoms:
See Section 11.
Notes to physician:
An individual having a dermal or pulmonary sensitization reaction to this
material should be removed from further exposure to any diisocyanate.Treat
symptomatically.
5. FIRE FIGHTING MEASURES
Extinguishing media:
Water spray (fog), foam, dry chemical or carbon dioxide. Do not use high
volume water jet.
Special firefighting procedures:
Wear self-contained breathing apparatus and full protective clothing, such as
turn-out gear. Keep unnecessary personnel away. During a fire, MDI vapors
and other irritating, highly toxic gases may be generated by thermal
decomposition or combustion.
Unusual fire or explosion hazards:
Closed containers may rupture (due to build up of pressure) when exposed to
extreme heat. Do not allow run-off from fire fighting to enter drains or water
courses. In case of fire, keep containers cool with water spray.
Hazardous combustion products:
Oxides of carbon, oxides of nitrogen, irritating organic vapors. Isocyanate
vapors.
6. ACCIDENTAL RELEASE MEASURES
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and
unprotected personnel.
Environmental precautions:
Do not allow product to enter sewer or waterways. Prevent further leakage or
spillage if safe to do so.
Clean-up methods:
Evacuate and ventilate spill area; dike spill to prevent entry into water system;
wear full protective equipment during clean-up. Refer to Section 8 "Exposure
Controls / Personal Protection" prior to clean up. Soak up with inert absorbent
material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape
up spilled material and place in a closed container for disposal.