Full Product Manual

Maestro Sensor
369666h 14 02.12.21
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Switch with Occupancy / Vacancy Sensor
Wiring Diagram 5 - with Neutral
Multi-Location Installation (120 V~)
1, 2, 4
-OPS5M, -OPS6M2-DV, -VPS5M, -VPS6M2-DV with MA-AS or MSC-AS
Blue
White
Ground
Occupancy
sensor switch
4
Black
Ground
120 V~
50 / 60 Hz
Brass
BrassBlack
Blue Blue
Green
Green
Ground
Hot / Live
Neutral
Load
MA-AS or
MSC-AS
MA-AS or
MSC-AS
Bare
Black Black
Wiring Diagrams (continued)
Wiring Diagram 5 - without Neutral
Multi-Location Installation (120 V~)
1, 2, 4
-OPS5M, -OPS6M2-DV, -VPS5M, -VPS6M2-DV with MA-AS or MSC-AS
Blue
Green-
sleeved
wire
Ground
Occupancy
sensor switch
4
Black
Ground
120 V~
50 / 60 Hz
Brass
BrassBlack
Blue Blue
Green
Green
Ground
Hot / Live
Neutral
Load
MA-AS or
MSC-AS
MA-AS or
MSC-AS
Bare
Black Black
1
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most occupancy sensor switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
2
Only one occupancy sensor switch can be used per multi-location circuit.
3
Fan load applies to 120 V~ only (not for 277 V~).
4
Occupancy sensor switch can be installed in any location.
Note: Connect green-sleeved wire to ground only in retrofit and replacement applications.
Note: When a neutral connection is available, remove the green sleeve and connect the white wire to neutral.
Continued on next page...
14