User Manual

Lynx L15ICE 18
SUBJECT: BIN CONTROL ADJUSTMENT FOR HIGHER ALTITUDE
The thermostac bin control ulized on the Lynx ice machines is
factory set for normal operaon. The factory seng is marked
on the bin control label with a red dot. It may be necessary in
areas of higher elevaon to make an addional adjustment.
The installaon instrucons recommend checking the bin control
for proper operaon during the start up of the unit. To check the
bin control, hold ice on the thermostac bin control bulb. The
unit 'should cycle o within 6 to 10 seconds. If addional
adjustment is required due to higher altude, turn the bin control
adjustment towards warm 1/8. turn and check again. When adjustment
is correct, the unit will cycle o as described above.
Maintenance
L15ICE
IMPORTANT
The icemaker must be maintained individually, referring to the instrucon manual and labels provided with the
icemaker.
1) Exterior
To keep the exterior clean, wipe occasionally with a clean and so cloth. Use a damp cloth containing a neutral
cleaner to wipe o all oil or dirt build-up.
2) Condenser
Check the condenser once a year, and clean the coil if required by using a brush or vacuum cleaner. More
frequent cleaning may be required depending on the locaon of the icemaker.