User Manual
Lynx L15ICE 18
SUBJECT: BIN CONTROL ADJUSTMENT FOR HIGHER ALTITUDE
The thermostac bin control ulized on the Lynx ice machines is
factory set for normal operaon. The factory seng is marked
on the bin control label with a red dot. It may be necessary in
areas of higher elevaon to make an addional adjustment.
The installaon instrucons recommend checking the bin control
for proper operaon during the start up of the unit. To check the
bin control, hold ice on the thermostac bin control bulb. The
unit 'should cycle o within 6 to 10 seconds. If addional
adjustment is required due to higher altude, turn the bin control
adjustment towards warm 1/8. turn and check again. When adjustment
is correct, the unit will cycle o as described above.
Maintenance
L15ICE
IMPORTANT
The icemaker must be maintained individually, referring to the instrucon manual and labels provided with the
icemaker.
1) Exterior
To keep the exterior clean, wipe occasionally with a clean and so cloth. Use a damp cloth containing a neutral
cleaner to wipe o all oil or dirt build-up.
2) Condenser
Check the condenser once a year, and clean the coil if required by using a brush or vacuum cleaner. More
frequent cleaning may be required depending on the locaon of the icemaker.