FACTORY SETTINGS
To reset the radio doorbell to factory settings, press and hold the learning code
button for 3 seconds until the control LED ashes blue. Release the button and
hold it down again until the control LED stops ashing. Aerthis, the radio door-
bell is back in the delivery state and no more transmitters have been learned.
Then switch the radio doorbell o and on again. The control LED ashes blue and
the radio doorbell is in learning mode. Now all the desired transmitters can be
taught in again. Please referto the section "Programmingtransmitters".
TECHNICAL DATA
Operating voltage: 230V / 50 Hz
Battery: 3.7V/600mAh lithium-polymer battery
Power consumption (batteryfully charged): <1W
Power consumption (battery being charged): approx. 2W
Frequency: 434MHz ; <10mW
Protection class: IP44
Temperature range: -20°C to +55°C
The battery is permanently installed; it can only be replaced by a specialist
workshop.