Specifications

Figure 4: RCS-3U-HIU smart battery charger
Figure 5: RC-SW-6 multibattery charging station
4.2 BATTERY CHARGING
To recharge the RB-14 battery pack using the RCS-3U-HIU smart charger (provided
with the SW-1000-SC), connect the charger (Fig. 4, #1) to the diver unit’s EM Hi-
Use
®
connector (Fig. 4, #2) and the power input cord (Fig. 4, #4) to the AC power
source (90–264 VAC, 50–60 Hz). Refer to the instruction sheet provided with the
RCS-3U-HIU charger for complete charging instructions.
If using the RC-SW-6 multi-battery smart charger, connect it (Fig. 5, #2) to the
diver unit’s EM Hi-Use
®
connector, and plug the power input cord (Fig. 5, #1) into
the AC power source. Refer to the RC-SW-6 user’s manual for more information.
IMPORTANT NOTE, MAG-1004HS only: Be sure to connect the chargers Hi-Use
®
connector (Fig. 4, #1 or Fig. 5, #2) to the SW-1000-SC’s EM cable (Fig. 4, #2),
not to its intercom coiled cord (Fig. 4, #3). Electrical current applied through the
coiled cord will not charge the batteries.
15
Key to Figure 4
(1) Charger’s Hi-Use
®
connector
(2) Non-coiled cord’s Hi-Use
®
con-
nector
(3) Coiled cord’s Hi-Use
®
connector
(4) AC power input plug
Key to Figure 5
(1) AC power input cord
(2) Charger’s Hi-Use
®
connector