Owner`s manual

Page 29
© 2009 Magnum Energy Inc.
Installation
Figure 2-15, AC Wiring for Dual In - Dual Out Con gurations
240
VAC only
in standby
Main Panel
(Utility /Generator Input)
MS Series Inverter
AC Terminal Block
(AC input and output wiring)
DUAL IN / DUAL OUT wiring
AC HOT 1 IN
(fro m Ma in P a nel)
AC HOT 1 OUT
(to Sub Panel)
AC NEUT IN
(fro m Ma in P a nel)
AC NEUT OUT
(to Sub Panel)
AC HOT 2 IN
(fro m Ma in P a nel)
AC HOT 2 OUT
(to Sub Panel)
Sub Panel and Outlets
(Inverter Loads)
120
VAC
120
VAC
AC GROUNDS
(to /from both
Panels)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
30
Maximum
30 amp breaker
(double pole)
required to
inverter AC input
30
In Mobile installations : neutral is typically not
connected to ground In main panel.