Installation Manual

Page 24
© 2015 Sensata Technologies
Installation
Main Panel
(Utility Power/Generator Input)
ME2012-15B or
ME2012-20B Inverter
AC Terminal Block
(AC input and output wiring)
SINGLE IN / DUAL OUT wiring
AC HOT 1 IN
(from Main Panel)
AC HOT 1 OUT
AC NEUT IN
(from Main Panel)
AC NEUT OUT
(x2)
AC HOT 2 OUT
Direct from inverter
(Inverter Loads)
120
VAC
120
VAC
AC GROUNDS
(to/from
both panels)
ON
OFF
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
30
Maximum breaker size required
to inverter AC input
depends on model used.
ME2012-15B: 45-amp breaker
(single pole);
ME2012-20B: 60-amp
breaker (single pole). These
breaker sizes allow full charging
and full pass-thru capability for
your inverter model.
In mobile installations: neutral is typically not
connected to ground in the main panel.
AC HOT 2 IN
(from Main Panel)
Has optional 15-amp or 20-
amp branch-rated circuit
breakers (on side of unit).
Figure 2-12, AC Wiring for Single In – Dual Out Con gurations