Page 18
© 2014 Magnum Energy, Inc.
Setup
METER: 03 Timers
03A Charge Time – This meter displays the total time the charger is holding the batteries
at a high voltage level—de ned as 0.2 volts greater than the oat voltage setting. The timer
counts when in the Bulk, Absorption, or Equalization charge stages (or in the Constant Cur-
rent and Constant Voltage charge stages if CC/CV is selected under the SETUP: 03C Battery
Type menu). The meter does not accumulate time when in Float, Charger Standby, Full, or
Silent mode. The charge timer resets whenever the charge status goes to “Charging” (AC
connected to inverter/charger), or the charger initiates another Bulk, EQ, or Constant Current
charge cycle.
Info: The displayed 03A Charge Time value is used by the Max Charge Time feature
to determine when to display “Max Charge Time,” and to blink the CHG LED indicator.
Info: The Max Charge Time safety feature is set and enabled based on the battery type
that is selected under the SETUP: 03C Battery Type menu:
a) If battery type is CC/CV – the Set Max CC/CV Time setting is available once Set CV
Chg Done Time (or Amps) is selected under the SETUP: 03C Battery Type/CC/CV menu.
b) If battery type is not ‘CC/CV’ – the SETUP: 03F Max Charge Time menu is available
to set the maximum charge time.
03B Since Absorb Done – This meter displays the number of days since the Absorption
charge mode was completed. This menu resets to zero once an Absorb Done parameter is met
as per the SETUP: 03D Absorb Done Time, Amps, or SOC settings.
Info: The 03B Since Absorb Done timer also resets to zero if the Absorption charge
mode is nished prematurely due to the starting of another charge mode—such as
enabling a Start Float charge (using CTRL: 02 CHG Control/Start Float).
03C Since EQ Start – This meter displays the number of days since the EQ charge mode has
been enabled. This menu resets to zero once equalization has started. The SETUP: 03H EQ
Reminder Days menu uses the time shown in this menu to determine when to indicate it is
time to perform an Equalization charge to the batteries.
METER: 04 AGS Meters
Refer to Section 7.0 for detailed information on the AGS meter menus that are available from the
ME-ARC remote’s METER button.
METER: 05 BMK Meters
Refer to Section 8.0 for detailed information on the BMK meter menus that are available from the
ME-ARC remote’s METER button.
METER: 06 ACLD Meters
Refer to Section 9.0 for detailed information on the ACLD meter menus that are available from
the ME-ARC remote’s METER button.
METER: 07 PT Meters
Refer to Section 10.0 for detailed information on the PT meter menus that are available from the
ME-ARC remote’s METER button.
3.2.4 SETUP Button and Menus
Pressing the SETUP button provides access to menu items and settings that enable you to con g-
ure the ME-ARC, inverter/charger, ME-AGS-N, ME-BMK, ACLD, and the PT controller. Review each
menu item to determine if you need to adjust any settings to meet your system requirements.
Info: The rst screen that may appear when the SETUP button is pushed is a password
screen. If the PIN has been set under the TECH: 05 SETUP PIN menu item, the rst
screen is the Setup PIN menu. The proper PIN must now be entered in order to access
the SETUP menus. After ve minutes from the last button push, the display automatically
returns to the remote’s Home screen and the PIN must be reentered in order to access
the SETUP menus. Refer to the TECH: 05 SETUP PIN section for more information.