Installation Manual

© 2014 Magnum Energy, Inc.Page 39
Setup
Resetting/Clearing a PIN
You can override a previously entered PIN. When “PIN = 0***” displays, press and hold the SE-
LECT knob until “PIN = 0000” displays (approximately 7 seconds). Enter a new PIN number.
TECH: 06 Ext Control
External Control is a read only menu. Magnum Energy has adopted an open protocol policy which
allows certain functions of the inverter/charger to be controlled externally—such as with a third
party communications device. “Yes” displays if any external device/software is controlling the
remote. This menu is designed to help Magnum Energy technical support personnel determine if
the inverter/charger is operating normally, or being controlled by a third party.
No Ext Control Indicates no third party network device is controlling any inverter/charger
functions or the ME-ARC remote.
Yes – When this display shows a number or a series of numbers (i.e., 04 05 10 20 ## ##
## ##), it indicates that one or more of the allowable functions of the inverter/charger is
currently being controlled externally. The number(s) displayed can be used by Magnum tech-
nicians to determine what function(s) in the inverter/charger is being controlled.
TECH: 07 Show all Menus
This menu enables you to have the ME-ARC remote display all available screens (YES), or to just
display those screens that pertain to the devices and accessories currently active (NO).
TECH: 08 Load Defaults
This menu restores factory defaults to all settings on the inverter/charger and to any defaults
on any accessories that are networked. To restore all defaults, depress the SELECT knob for 5
seconds (once countdown is nished the screen displays “DEFAULTS LOADED”). Refer to Table
3-3 for the remote’s inverter/charger default values (see also Table 7-6 and Table 10-1 for the
remote’s AGS and PT default values, respectively).
Info: For information on the factory default settings for any networked accessory, refer
to the owner’s manual for that accessory.
Info: If a PIN has been set and locked, it must be entered before the Load Defaults
menu can be used.
Table 3-3, Inverter/Charger Default Settings on ME-ARC
Menu Items Default Settings Menu Items Default Settings
Max Charge Amps 200 ADC VAC Dropout
80 VAC (AC1), 70 VAC (AC2)*
(Exports = 150 VAC)
Search Watts 5 Watts Battery Type Flooded
LBCO Setting
10 VDC (12v)
20 VDC (24v)
40 VDC (48v)
Absorb Done
Time = 2 Hrs
Amps = 20 ADC
SOC = 100%
AC In - Time 6:00A - 6:00P Max Charge Rate 100%
AC In - VDC
11.0-14.1 VDC (12v)
22.0-28.2 VDC (24v)
44.0-56.4 VDC (48v)
Max Charge Time 12.0 Hrs
AC In - SOC 80%, 100% SOC Final Charge Stage Multi
Power Up Always OFF ReBulk Volts 12.0 VDC
AC Input Amps 30A (AC1), 20A (AC2)* EQ Reminder Days OFF
* AC2 settings available on MSH4024RE models only.