162. On the passenger side shock tower, locate the
circular wire conduit. Cut the Ty-strap where it meets
the Fuse/Relay center. Using a small straight blade
screwdriver, genly pry the locking tabs free on the up-
per cover of the conduit to free the cover.
Conduit cover tab
Cut Ty-strap
163. Once the conduit cover has been removed, locate
the large PURPLE wire and cut it.
164. Using the Crimp/Shrink connectors supplied,
Connect the YELLOW wire from the Magnavolt
harness to the end of the purple wire that goes to the
Fuse/Relay center. Connect the GREY wire from
the harness to the end of the purple re that goes to
the rewall. Carefully tuck all the wire back into
the conduit and snap the top cover back into place.
Route the Grey and Yellow wires out at the Fuse/
Relay center.
To Fuse/Relay
center
To Firewall
GREY
WIRE
YELLOW
WIRE
PURPLE WIRE
161. Replace the cover with the Magnavolt attached
on to the Fuse/Relay center. Connect the Magnavolt
harness to the unit.
Fuse/Relay cover
Magnavolt harness
12/05