® RHS 980/980H Operation Manual MAHLE Clevite Inc., RTI Division 10 Innovation Drive York, Pennsylvania 17402 USA Phone: 717-840-0678 Toll Free: 800-468-2321 Web-site: www.rtitech.com Manifold Protected Under US Pat No.
CONGRATULATIONS You have purchased the finest Recovery, Recycling and Charging Machine certified to SAE Standard J2788! Fill out and return the Warranty Card within 90 days to activate warranty and free lifetime technical support.
TABLE OF CONTENTS Introduction ...................................................................................................... 4 Overview of the RHS980 and How to Operate it ............................................. 5 Startup & Safe Operation ................................................................................ 6 Special Considerations with R134a ................................................................. 6 Control Panel ...........................................................
TABLE OF CONTENTS Continued Oil Drain Maximum Level Minimum Vacuum Leak level High Voltage Flush Maintenance Options ................................................................................ 24 Calibration Check Perform Load Cell Site Calibration Perform Load Cell Shop Calibration Set Date and Time Input/Output Diagnostics Combo Filter Replacement Vacuum Pump Oil Replacement Change Operator Passwords Change Service Manager Password Print Parameters Total Capacities ...................................
INTRODUCTION RTI RHS980 Refrigerant Handling System is designed for use on R134a vehicles and is compliant with J2788 standard. Unit recovers 95% of automobile refrigerant systems and has a refrigerant recharge accuracy of +/- ½ ounce. It features fully automatic operation. All control functions of the RHS980 are designed to provide intuitive and rapid interaction with the service technician.
OVERVIEW OF THE RHS980 AND HOW TO OPERATE IT The RHS980 is designed for intuitive operation with menu driven prompts on the display. A few minutes spent reviewing the contents of this operation manual will enable the technician to understand and optimize the use of the RHS980 to provide customers with a professional A/C service. The display shows data such as the internal cylinder weight and prompts the technician for input using the alphanumeric keypad and various navigation buttons.
STARTUP & SAFE OPERATION Do not use a damaged unit. Check for shipping damage and place a claim with carrier if damage is discovered. Return the Warranty Card to activate technical support service and warranty coverage. The RHS980 should be operated by certified personnel only. The RHS980 should not be operated or serviced by any person who has not read all the contents of this manual. This manual describes normal operation and maintenance for the RHS980.
CONTROL PANEL 560-80450-00 AUTOMATIC 1 1 VACUUM 2 3 ABC DEF 4 5 6 GHI JKL MNO 7 8 9 PQRS TUV WXYZ * CLR 0 # SPACE U/M 3 DEF 4 5 6 JKL MNO 7 8 9 PQRS TUV WXYZ * RECYCLE 2 ABC GHI CLR AUTOMATIC RECYCLE CHARGE 0 # SPACE U/M VACUUM CHARGE YES START Pressing any one of these four buttons causes the RHS980 to jump to the respective procedure. The alpha-numeric keypad is used to enter data when prompted on the LCD screen.
FIRST TIME USE The first time a new RHS980 is powered up it will automatically perform a routine where the language is selected. The language can be changed later if desired in the Setup Mode. The RHS980 will arrive without any refrigerant. It will be necessary to put new refrigerant into the internal charge cylinder before any other sequences can be run. The amount of refrigerant which to be transferred is factory set at 18 LB (8.16 KG). This amount can be adjusted if desired.
E H S S X O T T A S A O M I N E I E / F I L T R T T O P T O E D S AMP L E E R F OR O I L CON T I N U E N D Inspect the identifier hose for traces of oil contamination. If oil is present in the hose, remove the contaminated hose section or replace the entire hose assembly. See REFRIGERANT IDENTIFIER MAINTENANCE section of manual. Press START key.
The Fill Cylinder procedure is complete when desired amount of refrigerant has been transferred. The Setup procedure allows changing the value and is covered in DEFAULT VALUES section in this manual. F I L L C Y L COMP L E T E AM T F I L L E D # # . # L B S T O P T O E N D Note: To fill to less than 18 LB (8.16 KG), close valve on cylinder of new refrigerant and allow procedure to complete. A minimum of 10 LB (4.53 KG) is suggested for truck service application.
AUTOMATIC OPERATION The AUTOMATIC function allows an operator to program an automatic recycle, vacuum, vacuum leak test and charge sequence. WE I GH T = # # . # A U T OMA T I C At the main menu screen, press the START key. L B S T AR T ? S I D P T AR T I NG RE F R I GERANT DEN T I F I ER O NOT CONNEC T HOS ES L E A S E WA I T . . .
Press YES key if you want to inject oil into the A/C system after the Vacuum process has been completed. After the vacuum process has been completed the RHS980 will prompt you to inject the desired amount of oil. Selecting oil injection will only allow charging refrigerant to the high side or both sides. Press NO key if no oil is to be injected into the A/C system. If the RHS980 unit is enabled for the HYBRID OIL FLUSH feature, the RHS980 will not allow you to inject oil into the A/C system.
S > > > S > > > Y S C X E # # # E # # # L # # # L # # # E # # # E # # # C T # # # C T # # # Select the engine configuration of the vehicle being serviced, if more than 1 option is available. Press YES key on the highlighted value to continue. Use ▲ or ▼ key to scroll the displayed arrow to the desired selection. E NG I NE If required, a screen to select the system for the vehicle being serviced will be shown. Press YES key on the highlighted value to continue.
C T S S HE I M T A TO The vacuum leak test will begin if selected earlier. The time left will be displayed. CK V A CUUM L E A K E L E F T # # M I N R T TO CON T I NUE P TO END L E A K T E S T S TOP TO END O I L N OW ADD If leak test fails, press STOP key to end process. Perform diagnostic on vehicle A/C system to find leak. Correct vehicle system before resuming A/C service. If vacuum test PASSED the RHS980 will progress to operation below.
D I SCONNEC T HS AND S T AR T A / C Close the high side coupler and disconnect from the vehicle system coupler. Start the engine and place the A/C system on max setting. Press START key. HOS E MA X While the engine and A/C system is running, liquid is being removed from the services hoses. This ensures only vapor remains in hoses. CON T I NUE ? E Q UA L I Z I N G H O S E S P L E A S E WA I T Close the low side coupler and disconnect from the vehicle system coupler. Turn off the vehicle engine.
PRINTING RESULTS The RHS980 has an optional printer which allows the operator to print data collected during the AC system service. Contact RTI for more information. If print to flash drive is enabled (SEE SELECTABLE OPTIONS) and a flash drive is attached to the USB port, a duplicate report will be generated. File naming convention is: YEAR, MONTH, DAY, SEQUENCE.TXT. Use any text editor software to view file contents. WE I GH T = # # .
If printing to a flash drive is enabled, then the screen to the left will be shown and the data will be printed to the flash drive. PR I N T I NG RE SU L T S T O F LA S H D R I V E P L E A S E WA I T… HIGH VOLTAGE OIL FLUSH An RHS980 configured from the factory to perform service on high voltage systems is designated RHS980H.
WE I GH T = F I L L # # . # Press ▼ key. L B C Y L I N D E R S T A R T ? WE I GH T = # # . # T E CH A L E R T L B Press ▼ key. D EMO S T A R T ? WE I GH T = # # . # H I GH V O L T A G E F L U S H L B O I L S T A R T ? Press START key. CON N E C T E X T F L US H T O L OW A N D A D A P T E R S I D E C O U P L E RS H I GH CON T I N U E ? Connect the HIGH and LOW side couplers with the supplied HIGH VOLTAGE OIL FLUSH adapter as shown below, open HIGH and LOW side couplers. Press the START key.
SETUP The setup procedure provides a means of setting options for various operation functions of the RHS980. WE I GH T = # # . # A U T OMA T I C WE I GH T = The initial screen displayed after turning on power will be as shown to the left. L B S T AR T ? # # . # SE T UP L B Press the ▼ key to scroll through screens until the setup screen shown to the left is displayed. Press the START key. S T AR T ? SELECTABLE OPTIONS SE L EC T A B L E The first screen will be for SELECTABLE OPTIONS.
AC CA P DB ►N O I N T ERNA L E X T ERNA L Default is NO. This enables the RHS980 to interact with the RTI Refrigerant Capacity Database. If NO is selected, the operator will not be prompted prior to charge to access the AC Capacity Database for the vehicle charge amount. Selecting external and having flash drive with the All Makes Database attached to the unit USB port, all other manufacturers charge capacities will be available. Press the ▲ or ▼ key to scroll to choices. Press START key.
V I N EN T RY ►Y E S NO Default is YES. OP ERA TOR ▲ ▼ I D This feature is not applicable to the base RHS980 and RHS980 with High voltage oil flush. Enabling this feature will compromise the functionality of the unit. Press START key. EN T RY Y E S ►N O Default is NO. ▲ ▼ A C T E S T MOD E ENA B L ED ? Y E S ►N O Default is NO. V ACUUM P UMP O I L T E S T ENA B L ED ? Y E S ►N O Default is NO. This feature is not applicable to the base RHS980 and RHS980 with High voltage oil flush.
A U T OMA T I C O I L DRA I N Y E S ►N O Default is NO. W E I G H I NG ENA B L ED ? A U T OMA T I C W E I G H I NG U V D Y E E NA B L E D ? Y E S ►N O Default is NO. This feature is not applicable to the base RHS980 and RHS980 with High voltage oil flush. Enabling this feature will compromise the functionality of the unit. Press START key. ▲ ▼ This feature is not applicable to the base RHS980 and RHS980 with High voltage oil flush. Enabling this feature will compromise the functionality of the unit.
This feature is not applicable to the base RHS980 and RHS980 with High voltage oil flush. Enabling this feature will compromise the functionality of the unit. Press START key I N I T I A L V A CUUM HO L D # # # # # M I CRON B E TWE E N 3 K & 9 K CON T I NUE ? This feature is not applicable to the base RHS980 and RHS980 with High voltage oil flush. Enabling this feature will compromise the functionality of the unit.
D EF A U L T TI M E 1 0 B E TWE E N During vacuum process, a vacuum leak process will be provided to check system for potential leaks. Default value is 10 minutes. Press START key. V A CUUM L E A K M I N 1 AND 9 9 M I N CON T I NUE ? The calibration of the weight scale in the RHS980 can be easily checked using this procedure. A steel ball of a precise weight is provided with the RHS980 for performing this calibration check. Unit must show positive weight on scale prior to selecting this procedure.
P C S S E Y H E R L O L FORM I N T E I NDER L OA P CA L I BRA EC T Y E S O Press YES key if a calibration is required. Otherwise, press NO key. Special RTI 10 KG (22 LB) weights are required to calibrate the scale, do not use steel ball supplied with the machine! Load cell calibration should be performed by qualified technicians only and should be performed at least once per year. Call RTI technical support for more information.
SE T D # # SE L EC Press YES key if adjustment to the date and time is required. Otherwise, press NO key. A T E AND T I ME ? # - # # - # # # # # : # # : # # T Y E S OR NO SE T T HE DA T E Y Y Y Y - MM MM - D D - Y CO SE T T H E YE A R # # # # SE T T H E MON T H # # Using ▲ or ▼ key, increase or decrease the month. Press START key to continue. SE T T HE DA Y # # Using ▲ or ▼ key, increase or decrease the day. Press START key to continue.
U S S S S E T T Inputs and outputs of devices in the RHS980 can be checked for diagnostic purposes. Press YES key. E ▲ ▼ TO CHANGE L EC T ED OU T PU T AR T TOGG L E S ON&OF F OP TO END Press ▲ or ▼ key to select various outputs. The output identification number will display on the screen. For a selected output, press the START key to toggle it on and off. Press STOP key to advance to next screen. Press ▲ or ▼ key to select various inputs. The input identification number will display on the screen.
One of the 20 optional passwords stored in the RHS980 can be used for password protection and can be changed by performing the operation to the left. Press START key to continue. CHANGE OP ERA TOR P A SS WO R D S ? SE L EC T E # S S N # T T T # A O Y E S OR NO If YES was selected you will see the next 7 subsequent screens. The RHS 980 will prompt to enter the service managers password, default is 5237, this password was previously used to enable the password protection feature.
P A S SWO R D S This screen will be shown after the Default Password has been accepted. Press START key to continue. ACCE P T ED CON T I NUE ? Enter the Service Managers new 4 digit password and press YES to continue. Important once the Service Managers default password has been changed, the password must be remembered to make any further changes.
The RHS980 records the total refrigerant which has been recycled. That total is displayed on this screen. Press START key to go to next screen. TOT A L RE F R I GERAN T RECYC L ED # # # # # L B CON T I NUE ? The RHS980 records the total refrigerant which has been charged. That total is displayed on this screen. Press START key to go to next screen. TOT A L RE F R I GERAN T CHARGED # # # # # L B CON T I NUE ? The RHS980 records the hours the vacuum pump runs.
WE I GH T = # # . # L B Press ▼ key. C H A RG E S T A R T ? WE I GH T = F I L L # # . # L B Press ▼ key. C Y L I N D E R S T A R T ? WE I GH T = # # . # T E CH A L E R T L B Press START key. D EMO S T A R T ? S E L E C T D EMO A U T OMA T I C M A NU A L Select either the AUTOMATIC mode or MANUAL mode, if AUTOMATIC mode is selected follow the subsequent 5 screens. If MANUAL was selected see below. Use the ▲ or ▼ key to change the selection. Press START key.
VACUUM PUMP MAINTENANCE Fill Port Oil must be periodically changed in the vacuum pump to ensure continued performance. The RHS980 will display a reminder after every ten hours of vacuum pump use. A drain port and fill port for the vacuum pump protrude through the rear wall of the RHS980 to the left of the handle. A sight glass for viewing the oil level in the vacuum pump is located on the end of the fill port. Remove Fill Port Cap to optimize fluid draining.
INLINE FILTER MAINTENANCE It is recommended that the inline filter elements be changed at a minimum of every 75 lbs of processed refrigerant. 1. Pressure gauges must read zero or less. If not, perform a recycle procedure. 2. Remove the red and blue service hoses from the connection ports on the rear of the RHS980. 3. Use a deep 5/8 inch socket on the hose connection fitting along with a 5/8 inch backing wrench to remove the filter element housing (as shown to right). 4.
PRINTER MAINTENANCE (Optional Item) The printer paper will require replacement and can be accessed on the rear of the RHS980. Paper is 58MM Wide X 45MM Diameter Thermal paper and can be found at most local office supply retailers. Replacement paper is available from RTI. Order Kit: 360 82218 00 Press the door release button to open cover as shown. Insert the paper with about 5mm of paper outside the printer. Close cover door. Light will indicate Green when printer is ready.
UPDATING PROGRAM, LANGUAGES AND AC DATABASE The RHS980 has the capability to easily update program functionality, screen languages and AC charge capacity database. This is accomplished by inserting a programmed flash drive into the USB slot in the rear of the unit and cycling power OFF and ON. RHS 9 8 0 BY R T I T E CHNO L OG I E S L OAD I NG UPDA T E If languages are loading, the following message will display.
FREQUENTLY USED RTI CONSUMABLE ITEMS RTI P/N ITEM DESCRIPTION 028 80035 04 028 80036 04 023 80095 00 023 80096 00 360 82175 00 011 80004 00 360 81733 00 026 80483 00 360 81618 00 360 80672 00 360 82219 00 026 80480 01 026 80480 02 026 80309 00 360 80012 00 360 82292 00 026 80560 00 360 82218 00 HOSE RED 9 FT .5 ACME X M14-1.5 HOSE BLU 9 FT .5 ACME X M14-1.5 COUPLING FSC HIGH RED M14-1.5 215010 COUPLING FSC LOW BLUE M14-1.
PARTS IDENTIFICATION 6 11 1 12 7 2 3 8 4 13 5 9 1 Manifold Assembly 2 In-line Hose Screen Filters 3 Service Hoses 4 New Refrigerant (not included) 5 Condenser Fan 6 Control Power Supply 7 Combo Filter 8 Charge Cylinder 9 Load Cell 14 15 16 17 18 10 Calibration Ball 19 11 Control Board 12 Vacuum Pump 13 Compressor (Maintenance Free) 14 High Pressure Gauge 15 Low Pressure Gauge 16 Display & Keypad 17 Power Switch 18 Oil Drain Bottle 19 Oil Fill Bottle (Not available for RHS9
NOTES 38