SR/SC Series "A" Woodburning Fireplace For Models: SC36A, SR36A SC42A, SR42A Homeowner's Installation and Operating Manual 948 SR cover 11/18/97 948 SC cover 11/18/97 For use in U.S./Canada Underwriter's Laboratories Report No. MH6018 DO NOT DISCARD THIS MANUAL: Retain for future use. 7412948 7/08 Rev.
SR/SC Series "A" Woodburning Fireplace Safety Information PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Description The SR/SC Series "A" fireplaces are solid fuel, woodburning premium fireplaces.
SR/SC Series "A" Woodburning Fireplace SR36A Series Woodburning Fireplace 48���" (1232mm) 5/8”(13mm) 22���" (572mm) 11" Dia. (279mm) 8���" (210mm) 8" Dia.
SR/SC Series "A" Woodburning Fireplace SR42A Series Woodburning Fireplace 26���" (667mm) Rough Opening Depth 50" (1270mm) 1/2" (13mm) 11" Dia. (279mm) 8" Dia.
SR/SC Series "A" Woodburning Fireplace B C A FP1531 Front Width Back Width Depth A SR/SC36A SR/SC42A B C FP1531 19⁷⁄₈" 15¹⁄₂" 31¹⁄₈" hearth dimensions (791 mm) (505 mm) (394 mm) 9/04 djt 22⁷⁄₈" 15¹⁄₂" 36³⁄₄" (934 mm) (581 mm) 394 mm) Fig. 4a Hearth dimensions. Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation.
SR/SC Series "A" Woodburning Fireplace Chimney Requirements - Offset Installations OFFSET CHIMNEY FLUE EXIT RISE CHIMNEY SECTION IWF282 30° RETURN ELBOW B A D E 6 FT. G 30° OFFSET ELBOW RISE C H OFFSET 30° RETURN ELBOW 30° OFFSET ELBOW B 30˚ Elbow Offsets G SKCS8 SUPPORT H HEARTH FLOOR Example 1 Example 2 Example 3 IWF269 Notes: G + H cannot exceed 20 feet.
SR/SC Series "A" Woodburning Fireplace Planning Information Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run. Mounting the Fireplace A fireplace may only be mounted on the following surfaces: 1. A flat combustible surface. 2. A raised wooden platform. 3. A concrete block or other solid object placed beneath each of the four (4) corners of the fireplace.
SR/SC Series "A" Woodburning Fireplace Installation Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9m) with SK8 chimneys or 20' (6m) with 3-wall chimneys. Locate chimney supports at ceiling holes or other structural framing at 30' (9m) (SK8) or 20' (6m) (3-wall) heights. Spacing between chimney supports must not exceed 30' (9m) (SK8) or 20' (6m) (3-wall).
SR/SC Series "A" Woodburning Fireplace Framing Option For Circulating Models Only — Framing can be constructed before or after the fireplace is set in place, however, most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1, 2, 3 or 4 for basic fireplace specifications. NOTE: Framing should be positioned to accommodate wall covering and fireplace facing material.
SR/SC Series "A" Woodburning Fireplace Straight-Up Chimney Installation To mark the centerline of the flue, put the fireplace in final position and measure out from the wall: 9¹⁄₄" (235mm). Mark a spot on the ceiling directly above the fireplace. Draw a line parallel to the back wall through this mark. (Fig. 11) Using a plumb bob positioned directly over center point of fireplace flue collar, mark the ceiling to establish the chimney center point. (Fig.
SR/SC Series "A" Woodburning Fireplace The following table gives firestop spacer model numbers: Angle of Chimney at Ceiling Vertical 30° SKFS2A SKFS6A 14¹⁄₂" x 14¹⁄₂" 14¹⁄₂" x 25¹⁄₂" (368mm x 368mm) (368mm x 648mm) 8" Flue FS2A FS6A "S" Series 3-Wall 17¹⁄₂" x 17¹⁄₂" 17⁷⁄₈" x 29⁵⁄₈" (445mm x 445mm) (454mm x 753mm) Fig. 13 Ceiling chimney hole sizes necessary for installing firestop spacer.
SR/SC Series "A" Woodburning Fireplace Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer. Pipe Section Installing the Firestop Spacer in the Ceiling Hole Pipe Rim UP Hem Lance Pipe Rim A firestop spacer is used to keep pipe spaced properly and required for safety. Nail the firestop spacer (at each corner) to the framing members of the ceiling hole. NOTE: A firestop spacer is not required at the roof.
SR/SC Series "A" Woodburning Fireplace NOTE: In the U.S., it is a good idea, although not always required, to install an attic insulation shield where blown-in insulation is planned to be used in the attic. Install the attic insulation shield with the flanges on its base extending down into the framing hole. Nail each corner of attic insulation shield to the framing members of the ceiling hole using 8d nails. Attic shields are not required at the roof. Penetrating the Roof Run pipe to roofline.
SR/SC Series "A" Woodburning Fireplace Installing Top Housing or Termination Air Space Clearances Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas). Follow the installation instructions provided with the chimney termination you have selected. Installing Chimney In a Chase Refer to Page 5, Figure 5 for an illustration of a typical chase installation. CAUTION: Treatment of firestop spacers and construction of chase may vary with type of building.
SR/SC Series "A" Woodburning Fireplace Mantel Clearance - Radiant Model - No Noncombustible Facing Material Combustible Mantel and Trim 12" (305mm) Max. 1���" (38mm) Mantel Clearance - Radiant Model - with Noncombustible Facing Material Combustible Mantel and Trim Finished Wall 1���" (38mm) Header 12" (305mm) Min. 12" (305mm) Max. 12" Standoff Noncombustible (305mm) Min. Material Radiant Surround Face * 6" (159mm) Min.
SR/SC Series "A" Woodburning Fireplace Side Wall Protection Hearth Installation Adjacent combustible side walls that are within the minimum dimensions shown in Figure 23 of fireplace opening must be protected with MHSC Wall Shield Model SP40 or a specifically built wall shield described below. A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 23 for minimum dimensions and mounting detail.
SR/SC Series "A" Woodburning Fireplace COMMON MATERIALS AND FACTORS MATERIAL EH2416 (MHSC) K* R 0.458 1.09 Common Brick 5.0 0.10 MINIMUM THICKNESS Side View Wall Covering Noncombustible Decorative Facing 0.50 in.** 2 x 4 Header (Do not notch at standoffs) Seal all cracks between fireplace surround and wall materials with noncombustible material 5.46 in.** R Value is for 1/2 inch.
SR/SC Series "A" Woodburning Fireplace Installing Line for Gas Logs Fireplace Top View Hole in Outer Casing MHSC fireplaces are designed to accept a 1/2" (13 mm) gas line for installation of an approved gas appliance. (MHSC manufactures a wide variety of gas logs for use in MHSC fireplaces.) Gas Line Tube Be sure to have the appliance installed in accordance with building codes. 1" Min. Repack Insulation Ceramic Knockout Gas connection may enter from either left or right side of the fireplace.
SR/SC Series "A" Woodburning Fireplace 1 9 2 11 4 6 b c d 3 a e 5 8 12 14 13 7 10 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. SR36A/42A, SC36A/42A SERIES For units FB40RO, GB40RO, FB40CO, GB40CO Ref. 1. 2. 3. 4. 5. 6a. 6b. 6c. 6d. 6e. 7. 8. 9. 10. 11. 12. 13. 14.
SR/SC Series "A" Woodburning Fireplace Accessories The following accessories for this appliance are available from your local Majestic Fireplaces distributor. Should you need additional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY 40361, Attn: Technical Services. CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be operated only with MHSC approved components.
SR/SC Series "A" Woodburning Fireplace Chimney Components U.S. Component Round Top Termination Round Top Termination Extended Flashing Square Termination Housing Adapter Kit Housing Extensions Square Chase Termination Adapter Kit Chase Top Housing Chase Top Housing SK8 Chimney Sections SK8 Chimney Elbows Firestop Chimney Support 7412948 Description Top used to terminate chimney at roof. (Flashing not included.) Top used to terminate chimney at chase. (Flashing not included.
SR/SC Series "A" Woodburning Fireplace (Chimney Components con't.) Canada Component Chimney Collar Enclosure Attic Insulation Shield SK8 Chimney Sections 45˚ Chimney Elbows 22 Description Installs on the "over the chimney collar" of the fireplace; provides outside air to assist in cooling the chimney system. Used to prevent insulation from coming in contact with the chimney system. Used to build chimney systems exposed above roof. Provides 45˚ offset and return. For Canadian installations only.
SR/SC Series "A" Woodburning Fireplace LIMITED WARRANTY Factory-Build Fireplace and Components (Except Blowers) What is Covered and For How Long Five-Year Coverage: For five years from the date this fireplace and components are first purchased for use, MHSC will, at its option, repair or replace any defective part of this fireplace or components, or refund to you a sum not to exceed the factory retail price in effect at the time of purchase.