2. USING ELECTRIC POWER
WARNING
■
Make sure that the appliance is switched OFF before connecting it to the generator.
■
Do not move the generator while it is running.
■
Be sure to ground the generator if the connected appliance is grounded. Failure to ground unit may
lead to electrical shock.
CONTROL PANEL
(EG441A, EG441AE, EG601A, EG601AE, EG671A, EG671AE )
(EG241A, EG321A, EG321AE)
Engine switch
[Electric starter model]
Key switch
[Electric starter model]
Key switch
AC receptacle 20A
AC receptacle 20A
DC circuit
breaker
Earth
(
ground
)
terminal
Volt meter
DC
receptacle
AC circuit
breaker
Engine switch
AC circuit
breaker
DC circuit
breaker
DC
receptacle
Volt meter
Earth
(
ground
)
terminal