Installation manual

INSTALLING
THE
GAS
LINE
STEP
5:
Seal
hole
around
gas
line
on
refractory wall
with cement or
any
other non-combustible
IMPORTANT:
Install
the
gas
line before finishing the material.
(Figure
33).
fireplace. If desired,
a
decorative
gas
appliance
may
be
installed. Use only
iron
pipe,
112"
size,
and
appropriate
STEP
6:
Finish installation
by
either
capping
the
gas
fittings. When installing gas line, a valve designed
for
line or attaching
a
gas
log,
installation outside the fireplace
is
required
(Figure
31).
CAUTION:
WHEN
USING
THE
DECORATIVE
The unit is
shipped
from Ihe factory ready for installa-
tion. The
gas
line may
be
installed
to
enter
the
fireplace
from either side. Refer
lo
Figure
5
for hole location.
The
gas
line
is
intended for connection to a decorative
gas
appliance incorporating an automatic shutoff device
and complying with the Standard for Decorative
Gas
Appliances for Installation
in
Vented Fireplaces, ANSl
221.60
Decorative
gas
appliance
should
be installed in
accordance with the National Fuel
Gas
Cde. ANSl
2223.1.
and
NFPA
54.
BEFORE DOING
ANYTHING,
MAKE
SURE
THE
GAS
VALVE
LOCATED
OUTSIDE
YOUR
FIREPUCE
IS
SHUT
OFF.
STEP
1:
Remove gas line cover.
Save
screws.
Re-
move insulation
from
inside gas conduit
sleeve.
Save insulation.
t
SLEEVE
,
SCREWS
SIDE
-GAS
LINE
STEP
2:
With
gas
line
conduit
sleeve
in place strike the
back of
the
refractory using
a
light punch.
STEP
3:
Install
a
7
inch
minimum nipple to
reach
inside
the fireplace. Allow enough
thread
to
install
cap
(or
elbow
if
continuing installation).
STEP
4:
Repack insulation into conduit sleeve all
around nipple. Replace screws. (Figure
32),
APPLIANCE
THE
FIREPLACE
DAMPER
MUST
BE
SET
IN
THE
FULLY
OPEN
POSITION.
THIS
INSTALLATION
IS
NOT
LISTED
BY
UNDERWRITERS
LABORATORIES,
INC,"
RADCO
LAB.
in
accordance
wIth
ICBO require-
ments
and
is
approved
for
use
with
this fireplace
model.
INSTALLATION
OF
GAS
LOG
LIGHTER
IF YOUR FIREPLACE
IS
PROVIDED
WITH
A
GAS
LINE
FOR ATTACHMENT TO
A
GAS
LOG LIGHTER,
PLEASE
FOLLOW
THESE INSTRUCTIONS CARE-
FULLY.
1)
BEFORE
DOING ANYTHING, MAKE
SURE
THE
GAS VALVE LOCATED OUTSIDE YOUR FIRE-
PLACE
IS
SHUT
OFF.
2)
REMOVE
THE
CAP
AT
END OF
GAS
PIPELINE
PROTRUDING
FROM
SlDE
OF
THE
REFRAC-
TORY.
(SEE
FIG.
33).
3)
CONNECT
FITTINGS:
TWO
-
112
INCH
DIA.
45"
ELBOW
ONE
-
112
INCH
DIA. CLOSE NIPPLE
4)
INSTALL GAS
LOG
LIGHTER MAX.
24'
LONG.
1/2
INCH DIAMETER TO
ELBOW.
(SEE
FlG.33)
GAS
LOG
LIGHTER MUST
BE
INSTALLED FLUSH
TO
ME
HEARTH FLOOR
OF
YOUR APPLIANCE.
DO
NOT
ELEVATE
GAS
LOG LIGHTER.
YOUR
GAS
LOG LIGHTER IS
NOW
READY
FOR
USE.