Owners manual

USB100 User’s Manual
2.6.1.1.2 How to Use GWUtilities
Below is an annotated screenshot of the main GWUtilities program window:
.
To use the program, perform the following steps:
1. Start the program.
2. Select the serial port to which the gateway is connected with the "Gateway Serial Port"
selector. For USB connected gateways, you can determine the port to which the gateway
is connected by opening the "Device Manager" and opening "Ports (COM & LPT)" and
observing the ports labeled "Maretron NMEA 2000 USB Gateway".
3. Select a NMEA 2000® PGN in the "NMEA 2000® PGNs" listbox.
4. A list of checkboxes representing possible NMEA 0183 translations from the selected
NMEA 2000® PGN will appear on the right hand side of the window. Sentence types
with check boxes selected will be generated when the selected NMEA 2000® PGN is
received. Sentence types with check boxes deselected will not be generated.
5. Repeat steps 3 and 4 until desired settings have been chosen. The gateway's settings
are updated in real time; therefore, there is no need to explicitly "save" the settings to the
gateway.
6. When you are finished, click the "Exit" button to exit the program.
If, at any time, you wish to restore the gateway to its factory configuration, click the "Load
Factory Defaults" button.