Installation Guide

*With and without LCD panels.
**Highest gas setting: set for Winter/High.
Lowest gas setting: set for Summer/Low.
Note: If your gas model features an LCD panel, the digital display will indicate the
outgoing water temperature.
This information is intended as a guideline based on typical residential
environments. Temperature increases will vary depending on the environment in
which the heater is used. Variables such as very low incoming water temperature
or higher than average gas pressure can result in higher temperature increases.
Higher incoming water temperature or lower than average gas pressure can result
in lower temperature increases. ALWAYS test the water with your hand to confirm
suitable temperature before use.
1716
Flow (GPM) / Tem Icrease (F)
Model*
5GPM
1.0GPM
1.5GPM
2.0GPM
2.5GPM
2.7GPM
3.0GPM
3.5GPM
4.0GPM
4.3GPM
96
48
32
25
-
-
-
-
-
-
34
17
11
9
-
-
-
-
-
-
129
64
43
32
-
-
-
-
-
-
34
17
11
9
-
-
-
-
-
-
-
100
67
50
40
37
30
-
-
-
68
34
23
17
14
13
9
-
-
-
-
143
95
71
57
-
48
41
36
33
88
44
29
22
18
-
15
13
11
10
Gas
Setting**
Highest
Lowest
Highest
Highest
Highest
Lowest
Lowest
Lowest
GA5L
Portable
GA5L
GA10L
GA16L
Not enough water flow
through the unit
Increase water flow through
the unit
* No need for electricity, starts with pulse ignition, powered by 2 D cell batteries.
Hot Water Outlet per Minute
Heat Loss
Exhaust Discharge Mode
Ignition
Energy Efficiency
Height x Width x Depth
Weight
Aplicable Water Pressure
5 LPM / 1.3 GPM
34,614 BTU/h
17" x 11,4" x 4,7"
11 lbs
10 LPM / 2.7 GPM
79,228 BTU/h
Flue Duct Type
54% - 87%
23,6" x 13,6" x 6,9"
21 lbs
3.6 - 145.0 PSI / 0.25 - 10 bar
2D Cell Battery Powered (not included)
16 LPM / 4.2 GPM
111,903 BTU/h
27,9" x 16,5" x 8,2"
29 lbs
Related Gas Pressure (PSI)
0.25 up to 0.5 PSI (NG) & 0.4 (LPG)
Gas Type
Liquid Propane Gas or Natural Gas
Activation Flow Rate
Maximmum Flow Rate
2 GPM 3.1 GPM
4.3 GPM
10 PSI 10 PSI 10 PSI
TECHNICAL SPECIFICATIONS
GAS 5L GAS 10L GAS 16L