5802 INTEGRATED AMPLIFIER / OWNER’S MANUAL
NO POWER
Examine the power cord to ensure that it is connected to both the AC mains connector and a working, un-switched electrical outlet.
Check the mains fuse accessible on the rear panel mains outlet.
Examine the electrical circuit breaker to ensure that power is being supplied to the electrical outlet to which the N
0
5805 / N
0
5802 is connected.
Make sure the N
0
5805 / N
0
5802 is not in
Standby
mode. The front-panel standby LED illuminates fully and continually when the N
0
5805 / N
0
5802 is
On. The LED flashes slowly when the N
0
5805 / N
0
5802 is in
Standby
mode.
REMOTE CONTROL DOES NOT OPERATE
Eliminate obstructions between the remote control IR transmitter and the IR receiver on the N
0
5805 / N
0
5802’s front-panel display.
Check the menu to make sure the front panel IR was not disabled.
Make sure the rear-panel IR input connector is not being used.
Make sure the remote control is positioned within 17 feet (5m) and within a 45-degree angle of the N
0
5805 / N
0
5802’s front panel.
Make sure the IR receiver on the N
0
5805 / N
0
5802's front-panel display is not exposed to intense sunlight, halogen light, or fluorescent light. This
can cause IR reception to become unreliable.
Replace the remote control batteries.
NO SIGNAL AT THE SPEAKER OR LINE OUTPUTS
Examine all audio cables to ensure a reliable connection between the N
0
5805 / N
0
5802 and all associated components.
Examine the speaker cables to ensure a reliable connection between the N
0
5805 / N
0
5802 and the speakers.
Make sure that the connected speakers are working by connecting one of them to another amplifier (if available).
Make sure the volume is set to an audible level (start at 30 and move slowly up from there).
Make sure the mute is deactivated. The word “Mute” appears on the front panel display when in Mute mode. Push the Mute button to return to
normal operation.
Make sure the Offset setting for the selected input is not reducing the volume to an inaudible level. See Setup/Input for more information.
Make sure all associated components are connected to working electrical outlets and powered On.
Make sure the source device connected to the selected N
0
5805 / N
0
5802 input is producing an output signal.
“MISSING” INPUT
Make sure the Name parameter for the selected input has not been set to Disabled in the
Setup
menu. (Refer to Setup/Inputs/ on page 18 for more
information.)