Product specifications

CashFlow
®
9520 / 9524 / 9528 Design Guide
©
MEI., 2003 Page 17 Rev: G1
Coin Validation Inhibits A, B, C, D, E, F
To inhibit coin acceptance the CashFlow
®
validator offers six individual inhibit inputs.
These inhibits operate for each mode as detailed in the following text.
Binary Coded Output Mode Inhibits - UK
The channels inhibited, for a given inhibit line becoming active are factory set by the
validator coin inhibit map option. When inhibit (A to F) is active, then coins for the channels
specified in the map will be inhibited. The default settings for the GB profile are:
Inhibit Line Coins inhibited
2
B Token
C Reserved
D 20p
E 5p, 10p, 50p old & new
1
Binary Coded Output Mode Inhibits - Euro
(BCO - EURO) Coin Inhibit
Coin
No.
ValueABCDE F
Coin 1 Token 1 1 X
Coin 2 Token 2 1 X
Coin 3 1c 1* X
Coin 4 2c 1* X
Coin 5 5c 1* X
Coin 6 10c 1* X
Coin 7 20c 1* X
Coin 8 50c X 1
Coin 9 1Eu X 1
Coin 10 2EU X 1
Coin 11 5Eu 1* X
X= RESERVED
*= GROUPED INHIBIT INPUT