ROUTING CONFIGURATION
The CF9524 exits routes are marked as (B, C & D) with (A) being the default exit route
CF9524 4-WAY SEPARATOR
Default Route = A
CF9528 8-WAY SEPARATOR
Default Route = 8
Coin Routing Priority
The CashFlow
®
9524/9528 differs from the CF 126/129 with regard to coin routing
priority. Coins can be routed to any exit as primary and secondary route. The
product defines the exit depending on the type being set as primary or secondary.
Example: If the chosen Primary Route = (a), the only Secondary routes available
can only be (b), C, D or B. Therefore (d) and (c) cannot be used as a secondary
route.
Coin Route Priority
1 Highest
2
3
4
5
6
7
CF9528 8-WAY
SEPARATOR
Default Route = 8
- Lowest
The CF952x Series can support two types of separator, a 4-way and an 8-way.
Default Route
Coin Reject
1
2
3
4
6
578
Coin Tube Exits
Cash Box Exits
Default Route
D
A
B
C
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
*Viewed
from top -
see arrow
above
* see below
Viewed from the top of
the manifold assembly