Instruction manual
27
FINISHED WALLFINISHED WALL
FRAMINGFRAMING
1/4"1/4"
COMBUSTIBLE FRAMINGCOMBUSTIBLE FRAMING
MEMBERS FACING MATERIALMEMBERS FACING MATERIAL
TO TOP OF SPACERS. TO TOP OF SPACERS.
USE ONLY NONCOMBUSTIBLEUSE ONLY NONCOMBUSTIBLE
MATERIALS BELOW TOP OF SPACERS.MATERIALS BELOW TOP OF SPACERS.
NONCOMBUSTIBLENONCOMBUSTIBLE
FACING MATERIALFACING MATERIAL
FIREPLACE FACEFIREPLACE FACE
STEEL LINTELSTEEL LINTEL
(OPTIONAL) (OPTIONAL)
SCREENED OPENINGSCREENED OPENING
OF FIREPLACEOF FIREPLACE
4"4"
(REF.)(REF.)
EXTEND LINE FROM OPPOSITE REAR OFEXTEND LINE FROM OPPOSITE REAR OF
FIREBOX THRU A POINT 4" IN FRONT OFFIREBOX THRU A POINT 4" IN FRONT OF
FIREPLACE FACE, AND 1" OUTSIDE OFFIREPLACE FACE, AND 1" OUTSIDE OF
SCREENED OPENING. SCREENED OPENING.
OUTLINE OFOUTLINE OF
FIREPLACEFIREPLACE
FIREBRICKFIREBRICK
IT IS RECOMMENDED THAT YOUIT IS RECOMMENDED THAT YOU
INSULATE OUTER AND INNER WALLSINSULATE OUTER AND INNER WALLS
OF CHASE. ALWAYS MAINTAIN THEOF CHASE. ALWAYS MAINTAIN THE
PROPER CLEARANCE.PROPER CLEARANCE.
1" AIR SPACE TO SIDES1" AIR SPACE TO SIDES
AND REAR OF FIREBOXAND REAR OF FIREBOX
USE ONLY NON-COMBUSTIBLE USE ONLY NON-COMBUSTIBLE
MATERIALS BELOW TOP MATERIALS BELOW TOP
OF SPACERS.OF SPACERS.
OUTSIDE AIR INLETOUTSIDE AIR INLET
SAFETY STRIPSAFETY STRIP
HEARTH EXTENSIONHEARTH EXTENSION
TOP EDGE OF FIREPLACE OPENINGTOP EDGE OF FIREPLACE OPENING
TOP EDGE OF FIREPLACETOP EDGE OF FIREPLACE
COMBUSTIBLE FRAMING MEMBERS COMBUSTIBLE FRAMING MEMBERS
FACING MATERIAL TO TOP OF SPACERS. FACING MATERIAL TO TOP OF SPACERS.
COMBUSTIBLE MANTELCOMBUSTIBLE MANTEL
12" MAXIMUM12" MAXIMUM
INSTALLATION OF NONCOMBUSTIBLE TRIM MATERIALS TO THE FRONT FACE OF THE FIREPLACEINSTALLATION OF NONCOMBUSTIBLE TRIM MATERIALS TO THE FRONT FACE OF THE FIREPLACE
CAUTION: DO NOT ALLOW ANY TRIM MATERIALS TO EXTEND CLOSER THAN 3/8-INCH TO THECAUTION: DO NOT ALLOW ANY TRIM MATERIALS TO EXTEND CLOSER THAN 3/8-INCH TO THE
VERTICAL EDGES OF THE FIREBOX OPENING IF GLASS DOORS ARE TO BE INSTALLED.VERTICAL EDGES OF THE FIREBOX OPENING IF GLASS DOORS ARE TO BE INSTALLED.
18" MINIMUM FROM FIREPLACE OPENING TOMINIMUM FROM FIREPLACE OPENING TO
BOTTOM OF A COMBUSTIBLE MANTEL, ASBOTTOM OF A COMBUSTIBLE MANTEL, AS
RECOMMENDED BY FIREPLACE MANUFACTURER.RECOMMENDED BY FIREPLACE MANUFACTURER.
(SEE NOTE BELOW REGARDING (SEE NOTE BELOW REGARDING
H2853H2853 CANOPY.) CANOPY.)
*
NOTE: IF AN APPROVED ANSI Z21.11.2 UNVENTED ROOM HEATER IS TO BE INSTALLED IN TNOTE: IF AN APPROVED ANSI Z21.11.2 UNVENTED ROOM HEATER IS TO BE INSTALLED IN THIS FIREPLACE, A MARTIN HIS FIREPLACE, A MARTIN
H2853 H2853
CANOPYCANOPY
MAY ALSO BE INSTALLED ON THE FIREPLACE TO REDUCE THE MAY ALSO BE INSTALLED ON THE FIREPLACE TO REDUCE THE
18"
RECOMMENDED CLEARANCE FROM THE TOP EDGE OF THE FIRE- RECOMMENDED CLEARANCE FROM THE TOP EDGE OF THE FIRE-
PLACE OPENING TO THE BOTTOM OF A COMBUSTIBLE MANTEL TO PLACE OPENING TO THE BOTTOM OF A COMBUSTIBLE MANTEL TO
12"
INSTEAD OF THE SPECIFIED INSTEAD OF THE SPECIFIED
18"
.
*
COMBUSTIBLE TRIM COMBUSTIBLE TRIM
MATERIALS MAY BE PLACEDMATERIALS MAY BE PLACED
WITHIN SHADED AREAS. WITHIN SHADED AREAS.
(NOTE: COMBUSTIBLE(NOTE: COMBUSTIBLE
MATERIALS MUST NOT MATERIALS MUST NOT
OVERLAP BLACK PAINTEDOVERLAP BLACK PAINTED
SURFACE OF FIREPLACE.)SURFACE OF FIREPLACE.)
INSTALLATION OF COMBUSTIBLE TRIM ALONG SIDES OF FIREPLACEINSTALLATION OF COMBUSTIBLE TRIM ALONG SIDES OF FIREPLACE
INSTALLATION OF COMBUSTIBLE MANTELINSTALLATION OF COMBUSTIBLE MANTEL
CAUTION: DO NOT COVER CAUTION: DO NOT COVER
OR RESTRICT VENT AREAS OR RESTRICT VENT AREAS
WITH ANY TRIM MATERIALS. WITH ANY TRIM MATERIALS.
WARNING: THE SPACE BETWEENWARNING: THE SPACE BETWEEN
THE FACE OF THE FIREPLACETHE FACE OF THE FIREPLACE
AND THE NONCOMBUSTIBLEAND THE NONCOMBUSTIBLE
FACING MATERIAL MUST BEFACING MATERIAL MUST BE
SEALED. FAILURE TO PROPERLYSEALED. FAILURE TO PROPERLY
SEAL THIS CRACK CAN CAUSE ASEAL THIS CRACK CAN CAUSE A
POSSIBLE FIRE HAZARD AND WILLPOSSIBLE FIRE HAZARD AND WILL
VOID THE MARTIN WARRANTY.VOID THE MARTIN WARRANTY.
FIGURE 30
FIGURE 29
FIGURE 31
TRIM INSTALLATION
53D9034. Rev 1 03/03
WARRANTY.